5
Electrical installation
Standard ABOX "MTA...-S01.-...-00"
Operating Instructions – MOVIFIT
®
MC
61
X45: I/O terminals for safety-related inputs/outputs with PROFIsafe option S11
(only with PROFIsafe option card S11)
WARNING
Danger due to unexpected unit behavior When you are using terminal X45 for safe
disconnection, you must observe the "MOVIFIT
®
MC/FC – Functional Safety" man-
ual.
Severe or fatal injuries may result.
• When using the PROFIsafe option S11, note the permitted wiring diagrams and
safety conditions in the "MOVIFIT
®
MC/FC – Functional Safety" manual.
1
11
11 12
12 13
13 14
1415
15 16
16
2 3 4 5 6
17
1718
18
7 8
11
1 2 3 4 5 6 7 8
12 13 14 15 16 17 18
31 32 33 34 35 36 37 38
21 22 23 24 25 26 27 28
X25
X29
1
11 12 13 14 15 16
2
3
4
5
6
1
2
3
4
11 12 13 14
X1
S3
1
1 2 3 4 5
11
1 2 3 4 5
12 13 14 15
2
3
4
1
2
3
4
X20
X71
X35
X50
1 2 3 4 5
X81
1 2 3 4 5
X91
X7
1
2
3
4
X8
X9
11
1 2 3 4 5
12 13 14 15
31 32 33 34 35
21 22 23 24 25
X45
1020626187
I/O terminals for safety-related inputs/outputs (only with option card S11)
No.
Name
Function
X45
1
F-DI00
Safety-related digital input F-DI00 (switching signal)
2
F-DI02
Safety-related digital input F-DI02 (switching signal)
3
F-DO00_P
Safety-related digital output F-DO00 (P switching signal)
4
F-DO01_P
Safety-related digital output F-DO01 (P switching signal)
5
F-DO_STO_P
Safety-related digital output F-DO_STO (P switching signal) for stopping the
drive safely (STO)
11
F-DI01
Safety-related digital input F-DI01 (switching signal)
12
F-DI03
Safety-related digital input F-DI03 (switching signal)
13
F-DO00_M
Safety-related digital output F-DO00 (M switching signal)
14
F-DO01_M
Safety-related digital output F-DO01 (M switching signal)
15
F-DO_STO_M
Safety-related digital output F-DO_STO (M switching signal) for stopping
the drive safely (STO)
21
F-SS0
+24 V sensor supply for failsafe inputs F-DI00 and F-DI02
22
F-SS0
+24 V sensor supply for failsafe inputs F-DI00 and F-DI02
23
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
24
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
25
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
31
0V24_O
0V24 reference potential for failsafe inputs/outputs
32
0V24_O
0V24 reference potential for failsafe inputs/outputs
33
0V24_O
0V24 reference potential for failsafe inputs/outputs
34
0V24_O
0V24 reference potential for failsafe inputs/outputs
35
0V24_O
0V24 reference potential for failsafe inputs/outputs
19484828/EN – 01/2015