5
Electrical installation
Standard ABOX "MTA...-S01.-...-00"
Operating Instructions – MOVIFIT
®
MC
62
X45: I/O terminals for safety-related inputs/outputs with S12A safety option
(only with S12A safety option)
WARNING
Danger due to unexpected unit behavior When you are using terminal X45 for safe
disconnection, you must observe the "MOVIFIT
®
MC/FC – Functional Safety with
S12 Safety Option" manual.
Severe or fatal injuries may result.
• When using the S12A safety option, note the permitted wiring diagrams and safe-
ty conditions in the "MOVIFIT
®
MC/FC – Functional Safety with S12 Safety Op-
tion" manual.
1
11
11 12
12 13
13 14
1415
15 16
16
2 3 4 5 6
17
1718
18
7 8
11
1 2 3 4 5 6 7 8
12 13 14 15 16 17 18
31 32 33 34 35 36 37 38
21 22 23 24 25 26 27 28
X25
X29
1
11 12 13 14 15 16
2
3
4
5
6
1
2
3
4
11 12 13 14
X1
S3
1
1 2 3 4 5
11
1 2 3 4 5
12 13 14 15
2
3
4
1
2
3
4
X20
X71
X35
X50
1 2 3 4 5
X81
1 2 3 4 5
X91
X7
1
2
3
4
X8
X9
11
1 2 3 4 5
12 13 14 15
31 32 33 34 35
21 22 23 24 25
X45
1020626187
I/O terminals for safety-related inputs/outputs (only with S12A safety option)
No.
Name
Function
X45
1
F-DI00
Safety-related digital input F-DI00 (switching signal)
2
F-DI02
Safety-related digital input F-DI02 (switching signal)
3
F-DO00_P
Safety-related digital output F-DO00 (P switching signal)
4
F-DO01_P
Safety-related digital output F-DO01 (P switching signal)
5
F-DO_STO_P
Safety-related digital output F-DO_STO (P switching signal)
for stopping the drive safely (STO)
11
F-DI01
Safety-related digital input F-DI01 (switching signal)
12
F-DI03
Safety-related digital input F-DI03 (switching signal)
13
F-DO00_M
Safety-related digital output F-DO00 (M switching signal)
14
F-DO01_M
Safety-related digital output F-DO01 (M switching signal)
15
F-DO_STO_M
Safety-related digital output F-DO_STO (M switching signal)
for stopping the drive safely (STO)
21
F-SS0
+24 V sensor supply for failsafe inputs F-DI00 and F-DI02
22
F-SS0
+24 V sensor supply for failsafe inputs F-DI00 and F-DI02
23
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
24
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
25
F-SS1
+24 V sensor supply for failsafe inputs F-DI01 and F-DI03
31
0V24_O
0V24 reference potential for failsafe inputs/outputs
32
0V24_O
0V24 reference potential for failsafe inputs/outputs
33
0V24_O
0V24 reference potential for failsafe inputs/outputs
34
0V24_O
0V24 reference potential for failsafe inputs/outputs
35
0V24_O
0V24 reference potential for failsafe inputs/outputs
19484828/EN – 01/2015