110
Operating Instructions – MOVITRAC® B
5
Communication and unit profile
Startup
Additional code
The additional code contains SEW-specific return codes for faulty parameterization of
the frequency inverter. They are returned to the master under
Error class 8 = other error
.
The following table shows all possible codings for the additional code.
MOVILINK
®
Additional code
Error class
High
Low
Description
0x05
00
0x00
Unknown error
0x01
Illegal Service
0x02
No Response
0x03
Different Address
0x04
Different Type
0x05
Different Index
0x06
Different Service
0x07
Different Channel
0x08
Different Block
0x09
No Scope Data
0x0A
Illegal Length
0x0B
Illegal Address
0x0C
Illegal Pointer
0x0D
Not enough memory
0x0E
System Error
0x0F
Communication does not exist
0x10
Communication not initialized
0x11
Mouse conflict
0x12
Illegal Bus
0x13
FCS Error
0x14
PB Init
0x15
SBUS - Illegal Fragment Count
0x16
SBUS - Illegal Fragment Type
0x17
Access denied
Not used
00
I
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......