Operating Instructions – MOVITRAC® B
6
DBG60B keypad
Operation
6.4.2
Information messages
Information messages on the DBG60B (ca. 2 s in duration) or in MOVITOOLS
®
Motion-
Studio/SHELL (message that can be acknowledged):
No. Text DBG60B/SHELL
Description
1
ILLEGAL INDEX
Index addressed via interface not available.
2
NOT IMPLEMENT.
•
Attempt to execute a function that is not implemented.
•
An incorrect communication service has been selected.
•
Manual mode selected via invalid interface (e.g. fieldbus).
3
READ ONLY VALUE
Attempt to modify a read only value.
4
PARAM. INHIBITED
Parameter lock
P803
= "ON", parameter cannot be altered.
5
SETUP ACTIVE
Attempt to change parameters while factory setting is active.
6
VALUE TOO HIGH
Attempt to enter a value that is too high.
7
VALUE TOO LOW
Attempt to enter a value that is too low.
8
REQ. CARD MISSING
The option card required for the selected function is missing.
-
10
ONLY VIA ST1
Manual mode must be completed using X13:ST11/ST12 (RS 485).
11
ONLY TERMINAL
Manual mode must be exited via TERMINAL (DBG60B or UWS21B).
12
NO ACCESS
Access to selected parameter denied.
13
CTRL. INHIBIT MISS-
ING
Set terminal DIØØ "/Controller inhibit" = "0" for the selected function.
14
INVALID VALUE
Attempt to enter an invalid value.
--
16
PARAM. NOT SAVED
Overflow of EEPROM buffer, e.g. through cyclic write access. Parameter
not saved in non-volatile EEPROM.
17
INVERTER ENABLED
•
Parameter to be changed can only be set in the state "CONTROLLER
INHIBIT".
•
Attempt to change to manual mode during live operation