140
Operating Instructions – MOVITRAC® B
7
List of faults (F00 – F113)
Service / list of faults
47
System bus 1
timeout
Stop without
inhibit
•
Fault during communication via
system bus
•
Check system bus connection
•
Check P808
•
Check voltage supply of FSE24B
•
Check EtherCAT communication
with connected FSE24B
77
IPOS control
word
Stop with inhibit
•
System error
•
Contact SEW Service
80
RAM test
Immediate switch-
off
•
Internal unit error, RAM defective
•
Contact SEW Service
81
Start condition
Immediate switch-
off with inhibit
Only in "VFC hoist" operating
mode:
The motor could not be supplied with
the correct amount of current during
the pre-magnetizing time:
•
Rated motor power too small in
relation to rated inverter power
•
Check connection between
inverter and motor
•
Check startup data and perform
new startup, if necessary.
•
Motor cable cross section too
small
•
Check cross section of motor
cable and increase if necessary.
82
Open output
Immediate switch-
off with inhibit
Only in "VFC hoist" operating
mode:
•
2 or all output phases interrupted
•
Check connection between
inverter and motor
•
Rated motor power too small in
relation to rated inverter power
•
Check startup data and perform
new startup, if necessary.
84
Motor protec-
tion
Stop with inhibit
•
Motor utilization too high.
•
Check
P345
/
P346
I
N
-UL moni-
toring
•
Reduce load
•
Extend ramps
•
Longer rest periods
94
EEPROM
checksum
Immediate switch-
off with inhibit
•
Defective EEPROM
•
Contact SEW Service
97
Copy error
Immediate switch-
off with inhibit
•
Parameter module is removed
during copying process
•
Switching off/on during copying
process
Prior to fault acknowledgement:
•
Load factory setting or complete
data set from parameter module
98
CRC error flash Immediate switch-
off
•
Internal unit error, flash memory
defective.
•
Send unit in for repair
100 Vibration/warn-
ing
Display fault
•
Vibration sensor warning (see
"DUV10A diagnostic unit" operat-
ing instructions)
•
Determine cause for vibration,
operation possible until
F101
101 Vibration error
Rapid stop
•
Vibration sensor signals fault
•
SEW-EURODRIVE recommends
that you remedy the cause of the
vibrations immediately
102 Oil aging/warn-
ing
Display fault
•
Oil aging sensor warns
•
Schedule oil change
103 Oil aging/fault
Display fault
•
Oil aging sensor signals fault
•
SEW-EURODRIVE recommends
that you change the gear unit oil
immediately.
104 Oil aging/over-
temperature
Display fault
•
Oil aging sensor signals overtem-
perature
•
Let oil cool down
•
Check if the gear unit cools prop-
erly
105 Oil aging/ready
signal
Display fault
•
Oil aging sensor is not ready for
operation
•
Check voltage supply of oil aging
sensor
•
Check and, if necessary, replace
the oil aging sensor
106 Brake wear
Display fault
•
Brake lining worn
•
Replace brake lining (see
"Motors" operating instructions)
No.
Designation
Response
Possible cause
Measures
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......