Operating Instructions – MOVITRAC® B
141
7
List of faults (F00 – F113)
Service / list of faults
110
Ex-e protection
Emergency stop
•
Duration of operation below 5 Hz
exceeded
•
Check configuration
•
Shorten duration of operation
below 5 Hz
111
System bus
(SBus) error
This error number signals the EtherCAT or fieldbus master
that the communication between FSE24B and
MOVITRAC
®
B is interrupted. MOVITRAC
®
B would
detect error 47.
•
Check FSE24B plug connection
113
Analog input
wire break
Programmable
•
AI1 analog input wire break
•
Check wiring
116
Error application module
Suberror:
14: Encoder error
29: Limit switch contacted
42: Lag error
78: Software limit switch reached
1) To set speed monitoring, changer parameter
P500
/
P502
and
P501
/
P503
. The sagging of hoists cannot be avoided safely if the delay
time is set to an excessively high value.
2) No reset required, error message disappears after communication is reestablished.
No.
Designation
Response
Possible cause
Measures