162
Operating Instructions – MOVITRAC® B
8
Technical data of the basic unit
Technical data
AC 230 V / 3-phase / size 3 / 11 / 15 kW / 15 / 20 HP
* With front module 4 mm (0.16 in)
MOVITRAC
®
MC07B (3-phase supply system)
0110-203-4-00
0150-203-4-00
Part number ("Safe stop" integrated)
828 510 1
828 512 8
INPUT
Nominal line voltage
V
line
3 × AC 200 – 240 V
Nominal line frequency
f
line
50/60 Hz ±5%
Nominal line current
(with V
line
= 3 × AC 230 V)
I
line
I
line 125
AC 40.0 A
AC 50.0 A
AC 48.6 A
AC 60.8 A
OUTPUT
Output voltage
V
O
3 × 0 – V
line
Recommended motor power 100% operation
Recommended motor power 125% operation
P
Mot
P
Mot 125
11 kW / 15 HP
15 kW / 20 HP
15 kW / 20 HP
22 kW / 30 HP
Nominal output current 100% operation
Nominal output current 125% operation
I
N
I
N 125
AC 42 A
AC 52.5 A
AC 54 A
AC 67.5 A
Apparent output power 100% operation
Apparent output power 125% operation
S
N
S
N 125
16.8 kVA
21.0 kVA
21.6 kVA
26.9 kVA
Min. perm. braking resistance
(4-quadrant operation)
R
BW_min
7.5
Ω
5.6
Ω
GENERAL INFORMATION
Power loss 100% operation
Power loss 125% operation
P
V
P
V 125
580 W
720 W
720 W
900 W
Type of cooling / cooling air consumption
Forced cooling / 180 m
3
/h
Current limitation
150% I
N
for at least 60 seconds
Unit terminal cross section / tightening torque
Terminals
25 mm
2
/ AWG4
3.5 Nm / 31 lb in
Dimensions
W × H × D
200 mm × 465 mm × 251 mm (7.87 in × 18.3 in × 9.88 in)
Mass
m
15 kg / 33 lb
*
200 (7.87)
105 (4.13)
445 (17.5)
7 (0.3)
465 (18.3)
251 (9.88)
247 (9.72)
P
i
f
kVA
Hz
n