Technical data for accessories and options
Technical data
Fieldbus gateways
Fieldbus gateways convert standard fieldbuses into the SEW SBus. This means that up
to 8 inverters can be triggered using one gateway.
The controller (PLC or PC) and the MOVITRAC
®
frequency inverter exchange process
data such as a control word or speed using the fieldbus. You need an FSC11B/12B com-
munication option for connecting the MOVITRAC
®
B unit to the fieldbus gateway. This
is also necessary if the gateway is integrated in the inverter. The FIO11B module cannot
be used for connecting.
You can basically connect and operate other SEW units (e. g. MOVIDRIVE
®
frequency
inverters) with the fieldbus via SBus.
There are two different versions of gateway functionality:
• Integrated in the inverter: The DF..B fieldbus interface is installed in MOVITRAC
®
B.
• In separate housing: The DF..B fieldbus interface is mounted in an UOH11B housing.
351335435
351336971
MOVITRAC® B
SBus
2
3
4
5
6
7
8
SPS / PLC
PROFIBUS
DeviceNet
EtherCAT
PROFINET
EtherNet/IP
PROFIBUS / PROFIsafe
®
PROFINET / PROFIsafe
®
1
MOVITRAC® B
SBus
2
1
3
4
5
6
7
8
SPS / PLC
PROFIBUS
DeviceNet
EtherCAT
PROFINET
EtherNet/IP
PROFIBUS / PROFIsafe
®
PROFINET / PROFIsafe
®
INFORMATION
If a fieldbus interface is factory-installed in MOVITRAC
®
B, then the SBus address
P881
is already factory set to "1".
In MOVITRAC
®
B without fieldbus interface, SBus address
P881
is preset to "0".