206
Operating Instructions – MOVITRAC® B
8
Technical data for accessories and options
Technical data
Interference emission with EMC-compliant
installation
Meets EN 61800-3:
•
with NF035-503 line filter (MDR60A0150-503-00)
•
with NF048-503 line filter (MDR60A0150-503-00)
•
with NF085-503 line filter (MDR60A0370-503-00)
•
with NF150-503 line filter (MDR60A0750-503-00)
Ambient temperature
ϑ
amb
Derating ambient temperature
0 °C to +40 °C
I
N
reduction: 3% I
N
per K to max. 60 °C
Climate class
EN 60721-3-3, class 3K3
Storage temperature
1)
ϑ
S
–25 °C to +70 °C (EN 60721-3-3, class 3K3)
Cooling type (DIN 51751)
Forced cooling
(temperature-controlled fan, response threshold 50 °C)
Degree of protection
size 2
EN 60529
size 3
(NEMA1)
size 4
IP20
IP20
IP00 (power connections)
IP10 (power connections)
•
With fitted plexiglass cover supplied as standard
•
With fitted shrink tubing (not included in scope of delivery)
IP20
•
with mounted DLB11B touch guard
Duty type
Continuous duty (EN 60149-1-1 and 1-3)
Overvoltage category
III according to IEC 60664-1 (VDE 0110-1)
Pollution class
2 according to IEC 60664-1 (VDE 0110-1)
Installation altitude
There are no restrictions for heights < 1000 m.
The following restrictions apply to heights
≥
1000 m:
•
From 1000 m to max. 4000 m:
–
I
N
reduction by 1% per 100 m
•
From 2000 m (6562 ft) to max. 4000 m (13120 ft):
–
The safe disconnection of power and electronics connections can no longer
be assured above 2000 m.
This requires external measures (IEC 60664-1/EN 61800-5-1).
–
You have to connect an overvoltage protection device in order to reduce the
overvoltages from category III to category II.
1) In case of long-term storage, connect the unit to the power supply for at least 5 minutes every two years, otherwise the unit's service
life may be reduced.
MOVIDRIVE
®
MDR60A
0150-503-00 (size 2)
0370-503-00 (size 3)
0750-503-00 (size 4)