226
Operating Instructions – MOVITRAC® B
8
Technical data for braking resistors, chokes and filters
Technical data
1-phase inverter
Use is required under the following circumstances:
• Unit load I
N
> 100 %
• Supply system inductances < 100 µH per phase
• Operation of several units that are switched simultaneously The line choke limits
overvoltages caused by the switching.
Use is optional in the following instances:
• Reduction of the supply system current harmonics
• To support overvoltage protection
Connecting sev-
eral single-phase
inverters on one
three-phase line
choke
Prerequisites for connecting several 1-phase inverters to one 3-phase line choke:
• The line contactor must be designed for the total current.
• The fuse must correspond to the nominal current of the line choke.
• The symmetric connection of the MOVITRAC
®
B to line choke.
3-phase inverters
Using line chokes is required when operating more than 5 inverters that are switched on
simultaneously. The line choke limits overvoltages caused by the switching.
Use is optional for supporting overvoltage protection.
Dimension drawing – line choke ND020.. / ND030.. / ND045.. / ND085..
1455926923
[1]
Space for installation terminals
Input: 1U1, 1V1, 1W1
Any mounting position
Output: 1U2, 1V2, 1W2
Line choke
type
Main dimensions mm (in)
Mounting dimensions mm (in)
Hole dimension
mm (in)
Mass
A
B
C
a
b
c
kg (lb)
ND020-013
85 (3.3)
60 (2.4)
120 (4.72)
50 (2)
31 - 42 (1.2 - 1.7)
5 - 10 (0.2 - 0.39)
0.5 (1)
ND030-023
ND045-013
125 (4.92)
95 (3.7)
170 (6.69)
84 (3.3)
55-75 (2.2 - 3)
6 (0.24)
2.5 (5.5)
ND085-013
185 (7.28)
115 (4.53)
235 (9.25)
136 (5.35)
56 - 88 (2.2 - 3.5)
7 (0.28)
8 (18)
a
c
c
C
A
[1]
[1]
1U1 1U2 1V1 1V2 1W1 1W2
B b
P
i
f
kVA
Hz
n