Operating Instructions – MOVITRAC® B
69
5
Keypads
Startup
7. Select the motor type. If a 2 or 4-pole SEW-
EURODRIVE motor is connected, select the correct
motor from the list.
If a non-SEW motor or an SEW motor with more than
four poles is connected, select "NON-SEW MOTOR"
from the list.
Use the
↑
key to choose the next parameter.
C02*MOTOR TYPE 1
DT71D2
DT71D4
DT80K2
C02*MOTOR TYPE 1
NON-SEW MOTOR
DT63K4/DR63S4
8. Enter the rated motor voltage for the selected connec-
tion type according to the value specified on the
nameplate.
Example: Nameplate 230
/400
50 Hz
connection
→
enter "400 V".
connection/transition point at 50 Hz
→
enter
"230 V".
connection, transition point at 87 Hz
→
Also enter
230 V. However, set parameter
P302 "MAXIMUM
SPEED 1"
to the value for 87 Hz after startup first.
Then start the drive.
Example: Nameplate 400
/690
50 Hz
Only
∆
connection possible
→
enter "400 V".
connection is not possible.
Use the
↑
key to choose the next parameter.
C03* V
NOM. MOT. VOLT 1
+400,000
9. Enter the nominal frequency specified on the motor
nameplate.
Example: 230
/400
50 Hz
Enter "50 Hz" for
and
connection.
Use the
↑
key to choose the next parameter.
C04* Hz
NOM. MOT. FREQ. 1
+50,000
FOR SEW MOTORS
10. The motor values are stored for SEW 2 and 4-pole
motors and need not be entered.
C47*4-Q OPERATION
NO
YES
FOR NON-SEW MOTORS
00
I
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......