Operating Instructions – MOVITRAC® B
125
6
Data backup
Operation
6
Operation
6.1
Data backup
6.1.1
Data backup using FBG11B
Use the FBG11B keypad to download parameter data from the MOVITRAC
®
B to the
keypad or copy from the keypad to MOVITRAC
®
B.
Check that the required data set has been copied to the inverter.
Data backup with FBG11B
After copying data, the MOVITRAC
®
B is inhibited. The inhibited status is indicated by
a flashing STOP in the status display. The status LED also slowly flashes yellow.
You can revoke the inhibit by taking one of the following measures:
• Press the RUN key on the FBG11B.
• Switch off the power supply, wait for 10 seconds and switch the power back on.
6.1.2
Data backup using DBG60B
Copy the parameter set from MOVITRAC
®
B to the DBG60B keypad. You have the fol-
lowing options:
• In the context menu, select the "COPY TO DBG" menu item. Confirm your selection
by pressing OK. The parameter set is copied from MOVITRAC
®
B to DBG60B.
• In the context menu, select the "PARAMETER MODE" menu item. Select parameter
P807 copy MOVITRAC
®
B
→
DBG
. The parameter set is copied from
MOVITRAC
®
B to DBG60B.
• Press the run key of FB11B or DBG60B, or switch the unit off and on again.
25352587
Enter
Enter
Level 2