130
Operating Instructions – MOVITRAC® B
6
Return codes (r19 – r38)
Operation
6.3
Return codes (r19 – r38)
Return codes when entering / editing a unit parameter in the FBG11B:
No.
Designation
Meaning
18
Only read access
Parameter cannot be changed
19
Parameter lock activated
Parameters cannot be changed
20
Factory setting in progress
Parameters cannot be changed
23
Option card missing
The option card required for the function is missing.
27
Option card missing
The option card required for the function is missing.
28
Controller inhibit required
Controller inhibit required
29
Invalid value for parameter.
•
Invalid value for parameter.
•
FGB manual operation selection invalid as PC is
in active manual operation.
32
Enabled
You cannot perform this function in ENABLED status
34
Error in sequence
•
Error while saving in FBG11B.
•
Startup not performed with FBG. Perform startup
with MotionStudio or select a new motor.
38
FBG11B incorrect data set
Stored data set does not match the unit
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......