Operating Instructions – MOVITRAC® B
133
6
DBG60B keypad
Operation
6.4.3
Functions of the DBG60B keypad
Key assignments
for DBG60B
Copy function of
the DBG60B
You can use the DBG60B to copy entire parameter sets from one MOVITRAC
®
B unit
to other MOVITRAC
®
B units. Proceed as follows:
• In the context menu, select the menu item "COPY TO DBG". Confirm your selection
by pressing OK.
• After the copying process has finished, plug the keypad in the other inverter.
• In the context menu, select the menu item "COPY TO MC07B". Confirm your selec-
tion by pressing OK.
• After copying, press RUN.
247460747
[1]
STOP key
Stop
[2]
↑
key
Up arrow, moves up to the next menu item
[3]
RUN key
Start
[4]
OK key
OK, confirms the entry
[5]
Context key
Activate the context menu
[6]
↓
key
Down arrow, moves down to the next menu item
[7]
. key
Decimal point
[8]
± key
Sign reversal
[9]
Keys 0 – 9
Digits 0 – 9
[10]
↔
key
Change menu
[11] Language key
Select language
[12] DEL key
Delete previous entry
[1]
[2]
[3]
[4]
[5]
[6]
[8]
[7]
[9]
[10]
[12]
[11]