Operating Instructions – MOVITRAC® B
153
8
Technical data of the basic unit
Technical data
AC 400/500 V / 3-phase / size 3 / 15 / 22 / 30 kW / 20 / 30 / 40 HP
* With front module 4 mm (0.16 in)
MOVITRAC
®
MC07B (3-phase supply system)
0150-503-4-00
0220-503-4-00
0300-503-4-00
Part number ("Safe stop" integrated)
828 528 4
828 529 2
828 530 6
INPUT
1)
1) The line and output currents must be reduced by 20% from the nominal values for V
line
= 3 × AC 500 V.
Nominal line voltage
V
line
3 × AC 380 – 500 V
Nominal line frequency
f
line
50/60 Hz ±5%
Nominal line current
(at V
line
= 3 × AC 400 V)
I
line
I
line 125
AC 28.8 A
AC 36.0 A
AC 41.4 A
AC 51.7 A
AC 54.0 A
AC 67.5 A
OUTPUT
Output voltage
V
O
3 × 0 – V
line
Recommended motor power 100% operation
Recommended motor power 125% operation
P
Mot
P
Mot 125
15 kW / 20 HP
22 kW / 30 HP
22 kW / 30 HP
30 kW / 40 HP
30 kW / 40 HP
37 kW / 50 HP
Nominal output current 100% operation
Nominal output current 125% operation
I
N
I
N 125
AC 32 A
AC 40 A
AC 46 A
AC 57.5 A
AC 60 A
AC 75 A
Apparent output power 100% operation
Apparent output power 125% operation
S
N
S
N 125
22.2 kVA
27.7 kVA
31.9 kVA
39.8 kVA
41.6 kVA
52.0 kVA
Min. perm. braking resistance
(4-quadrant operation)
R
BW_min
15
Ω
12
Ω
GENERAL INFORMATION
Power loss 100% operation
Power loss 125% operation
P
V
P
V 125
550 W
690 W
750 W
940 W
950 W
1250 W
Type of cooling / cooling air consumption
Forced cooling / 180 m
3
/h
Current limitation
150% I
N
for at least 60 seconds
Unit terminal cross section / tightening torque
Terminals
25 mm
2
/ AWG4
25 mm
2
/ AWG4
25 mm
2
/ AWG4
3.5 Nm / 31 lb in
Dimensions
W × H × D
200 mm × 465 mm × 251 mm (7.87 in × 18.3 in × 9.88 in)
Mass
m
15 kg / 33 lb
*
200 (7.87)
105 (4.13)
445 (17.5)
7 (0.3)
465 (18.3)
251 (9.88)
247 (9.72)
P
i
f
kVA
Hz
n
Summary of Contents for Movitrac B