Operating Instructions – MOVITRAC® B
165
8
Technical data of the basic unit
Technical data
AC 230 V / 1-phase / size 0XS / 0.25 / 0.37 kW / 0.34 / 0.50 HP
* With front module 4 mm (0.16 in)
MOVITRAC
®
MC07B (1-phase supply system)
0003-2B1-4-00
0004-2B1-4-00
Part number (without "safe stop")
828 491 1
828 493 8
INPUT
Nominal line voltage
V
line
1 × AC 200 – 240 V
Nominal line frequency
f
line
50/60 Hz ±5%
Nominal line current
(with V
line
= 1 × AC 230 V)
I
line
I
line 125
AC 4.3 A
AC 5.5 A
AC 6.1 A
AC 7.5 A
OUTPUT
Output voltage
V
O
3 × 0 – V
line
Recommended motor power 100% operation
Recommended motor power 125% operation
P
Mot
P
Mot 125
0.25 kW / 0.34 HP
0.37 kW / 0.50 HP
0.37 kW / 0.50 HP
0.55 kW / 0.74 HP
Nominal output current 100% operation
Nominal output current 125% operation
I
N
I
N 125
AC 1.7 A
AC 2.1 A
AC 2.5 A
AC 3.1 A
Apparent output power 100% operation
Apparent output power 125% operation
S
N
S
N 125
0.7 kVA
0.9 kVA
1.0 kVA
1.3 kVA
Min. perm. braking resistance
(4-quadrant operation)
R
BW_min
27
Ω
GENERAL INFORMATION
Power loss 100% operation
Power loss 125% operation
P
V
P
V 125
30 W
35 W
35 W
45 W
Type of cooling / cooling air consumption
Natural convection / –
Current limitation
150% I
N
for at least 60 seconds
Unit terminal cross section / tightening torque
Terminals
4 mm
2
/ AWG12 / 0.5 Nm / 4 lb in
Dimensions
W × H × D
54.5 mm × 185 mm × 163.5 mm (2.15 in × 7.28 in × 6.437 in)
Mass
m
1.3 kg / 2.9 lb
220 (8.66)
196 (7.72)
49.5 (1.95)
54.5 (2.15)
6 (0.2)
6 (0.2)
163.5 (6.437)
185 (7.28)
285 (1
1.2)
159.5 (6.280) *
149 (5.87)
P
i
f
kVA
Hz
n
Summary of Contents for Movitrac B
Page 2: ...SEW EURODRIVE Driving the world...
Page 259: ......