188
Operating Instructions – MOVITRAC® B
8
Technical data for accessories and options
Technical data
8.2.4
Fieldbus connection
DFP21B fieldbus interface for PROFIBUS
Part number: 1820 962 9
1823 840 8 as a kit with suitable screws.
Description
With the powerful, universal fieldbus interface option DFP21B, the MOVITRAC
®
B
frequency inverter can be connected to higher-level automation systems via PROFIBUS
DP and DP-V1.
Refer to the publication "Fieldbus interface DFP21B PROFIBUS DP-V1" for installation.
Electronics data
DFP21B option
External voltage
supply via X26
U = DC 24 V (–15%, +20%)
I
max
= DC 200 mA
P
max
= 3.4 W
PROFIBUS proto-
col variants
PROFIBUS DP and DP-V1 according to IEC 61158
Automatic baud
rate detection
9.6 kBd – 12 MBd
Connection tech-
nology
•
Via 9-pin D-sub connector
•
Pin assignment according to IEC 61158
Bus termination
Not integrated, must be implemented using suitable PROFIBUS
connector with terminating resistors that can be switched on.
Station address
1 – 125, can be set via DIP switches
GSD file name
SEW_6009.GSD
DP ID number
6009
hex
= 24585
dec
Application-spe-
cific parameter-
setting data
(Set-Prm-User-
Data)
•
Length: 3 bytes
•
Hex parameter setting 00,00,00
DP configura-
tions for
DDLM_Chk_Cfg
See publication "Fieldbus Interface DFP21B PROFIBUS DP-V1".
Diagnostics data
Standard diagnostics: 6 bytes
DFP21B
RUN
BUS
FAULT
X30
2
0
2
1
2
2
2
3
2
4
2
5
2
6
AS
0
1
P
i
f
kVA
Hz
n
Summary of Contents for Movitrac B