49
7 Adjustment menu
CH
4
- sensitivity 100 %VOL
now release
test gas 100 %VOL
CH4
from the SPE VOL
alternatively you can dispense
with the SPE VOL and use
natural gas from the local
supply
instead
wait for the display to settle at
a stable value and confirm the
adjustment with the on/off key
(
OK
appears in the LCD)
once this has happened, turn
off the test gas feed
Note:
Before switching to the next step, please wait until
the displayed concentration has reached the value
of 0 vol.%!
pressing the
arrow-up key
brings you to the next display
CH
4
- %UEG-range language
repeatedly pressing the on/off
key switches between the fol-
lowing displays in the %UEG
range:
%UEG
- display in
U
ntere
E
xplosions
g
renze (D)
%LEL
- display in
L
ower
E
xplosive
L
imit (GB)
%LIE
- display in
L
imite
I
nférieure d´
E
xplosion (F)
%VOL
- display in
%VOL
(D/GB)
%GAZ
- display in
%GAZ
(F)