3 Measuring operation
3.3
Modes
GAS-WARNING mode
Monitoring the atmosphere in shafts and chambers (cf. sec-
tion 1.2: Fields of application)
immediately after being
switched on the
EX-TEC Combi
is always in warning mode
Indication:
all alarm thresholds are
activated
Indication:
each available gas is dis-
played for about 3 seconds
before switching to the next
Sequence:
CH
4
- CO
2
- O
2
- H
2
S - CO
Every 5 seconds an operating
signal is activated as a marker.
It is both, acoustic (item 7) and
optical (item 1). The optical
signal acts as a control that
the instrument is functioning
in
gas-warning
mode.
If the operating signal is
switched off, the monitoring
of the gas concentration
is no longer insured. The
endangered area must be left
immediately.