17
3 Measuring operation
3.6
Instantaneous value alarms (AL1, AL2, AL3)
when in
gas-warning
mode
the
EX-TEC Combi
is con-
stantly in alarm readiness
this is displayed in the LCD
by two symbols:
Ex-area
and
alarm threshold
the alarm is triggered as soon
as a threshold is breached
Display of alarm thresholds
holding down the
threshold
value key
displays the set
alarm thresholds for the per-
tinent gas
Methane CH
4
alarm thresholds (factory set-
tings):
AL1 = 0.90 %VOL = 20 %LEL
AL2 = 2.20 %VOL = 50 %LEL
Carbon dioxide CO
4
alarm thresholds (factory set-
tings):
AL1 = 0.50 %VOL (MAK value)
AL2 = 1.00 %VOL