19
8 Troubleshooting
Troubleshooting
8
Troubleshooting
Possible sources of problems with the SePem 01 GSM are:
Fault with the
GSM Logger
Quality of the network connection
The quality of the network connection may vary considerably. For
example, this can be affected by the weather and parked cars. In
practice, this means that a network connection may suddenly be
lost, even if it has previously been verified using a test SMS.
SEWERIN Service will be pleased to provide assistance in cases
where the tips in the following chapters do not help in identifying
the cause of a fault (Tel.: +49 5241 934-250).
8.1
Problems with the GSM Logger
Problem/symptom
Cause > Solution
Logger cannot be activat-
ed (LED does not flash)
Flat battery > send Logger to
SEWERIN Service
Magnet too weak > Use a gen-
uine magnet of the type used
with the Logge
r
LED flashing
Initially normal
Rapid flashing after 90 s
The logger switches off
after another 3 s.
SIM card not installed in Log-
ger > Insert SIM card
(see Section 6.1)
SIM card inserted incorrectly >
Reinsert SIM card
(see Section 6.1)