background image

                      

11 

3-3. THE OTHERS 

 

1)  S/W    CONNECTOR   

l

 

SE7300 

SW No. 

Define 

Serial Baud Rate 

OFF 

OFF 

9600 bps   

ON 

OFF 

  192000bps 

OFF 

ON 

  115200bps 

ON 

ON 

  2400bps 

HanGul Type 

OFF 

WANSUNG 

ON 

JOHAP 

Control Command 

ON 

EPSON 

OFF 

INTERNAL 

Columns 

OFF 

OFF 

30Columns   

ON 

OFF 

40Columns 

OFF 

ON 

  24Columns 

ON 

ON 

  24Columns 

Parity 

OFF 

OFF 

None Parity 

ON 

OFF 

Odd Parity 

ON 

ON 

Even Parity 

 

* Default    mode on factory - out 

2)  POWER CONNECTOR   

 

  CONNECTOR   

  DC +12V or 24V 1.5A   

  GND   

                      

12 

4. OUTER APPARANCE 

 

       

 

4-1. SE7300 

 

 

 

 

Summary of Contents for SE7300 SD

Page 1: ...7300 PD SE7300 ST SE7300 PT 2 CONTENTS 1 OUTLINE 1 1 FEATURE 1 2 APPLICATION 2 OPERATION 2 1 SPECIFICATION 2 2 EXPLANATION OF EACH OTHER 2 3 SELF TEST 2 4 DUMP MODE 3 CONNECTIONS 3 1 SERIAL INTERFACE 3 2 PARRALL INTERFACE 3 3 THE OTHERS 4 OUTER APPEARANCE 4 1 SE7300 ...

Page 2: ...l dump mode applied l Graphic printing and bar code function are available 1 2 APPLICATION l Instruments and inspection system l INDICATOR and scale l F A system l A receipt l POS SYSTEM l Parking system l Various data recording 4 2 OPERATION 2 1 SPECIFICATION ITEM SPECIFICATION DESIGN PANEL TYPE PRINT METHOD DOT Matrx MACHANISM COLUMNS 24 30 40 ON ENGLISH FONT SIZE 40COL ENGLISH 6x12 KOREAN 12x12...

Page 3: ...ere is sufficient paper On pressing FEED S W SE7300 and power ON starting the self test After ending the self test continually press FEED S W SE7300 Then print HEX DUMP PRINT START after 2 seconds Thought you don t touch any s w the printer take out HEXA mode changed data from host If power off printer s recovered to normal mode 6 3 CONNECTIONS 3 1 Serial interface 1 Serial RS 232C Data Transmissi...

Page 4: ...ve data or not l Can do it on SPACE not do it on MARK when setting DTR DSR control l It s on MARK as bellows Full buffer in printer Operating on error On self test 25PinD SUBConnector MALE Printer RXD 2 TXD 3 DTR 4 GND 5 DSR 6 2 TXD 3 RXD 6 DSR 7 GND 20 DTR 9PinD SUBConnector FEMALE HOST 8 3 2 Parallel interface 1 Parallel Data Transmission 8 bit parallel Handshaking STROBE and BUSY or ACK Connect...

Page 5: ...l HIGH on normal LOW on operatong 11 BUSY OUT l Indicate Whether printer could receive data or not l Can not receive on HIGH can do it on LOW 12 PE OUT l Paper is or not l No paper on HIGH set it on LOW 13 SLCT OUT l Whether printer is ON LINE or not NC 14 AUTO FD IN l 1Line space is advanced on auto feed NC 15 ERROR OUT l Checking printer ERROR 16 INIT IN l Hardware Reset in printer NC 17 SLCT IN...

Page 6: ...0bps 3 HanGul Type OFF WANSUNG ON JOHAP 4 Control Command ON EPSON OFF INTERNAL 5 6 Columns OFF OFF 30Columns ON OFF 40Columns OFF ON 24Columns ON ON 24Columns 7 8 Parity OFF OFF None Parity ON OFF Odd Parity ON ON Even Parity Default mode on factory out 2 POWER CONNECTOR CONNECTOR DC 12V or 24V 1 5A G GND 12 4 OUTER APPARANCE 4 1 SE7300 ...