English
7. Troubleshooting
43
Message
Solution
Please change fuel cartridge
(Error 20, 21, 22, 23)
Insert a new fuel cartridge as described in Chapter 5.1.
Check cartridge hose for kinks. Check hose and
connection for dirt. Position fuel cartridge on the same
level as unit.
Check connection and screw cartridge on tightly.
Please refill service fluid
(Error 30, 31)
Check that exhaust can escape and that ambient
temperature is below 40° C. Then add service fluid
(see Chapter 7.4).
Please defrost device slowly
(Error 40)
Unit has been exposed to temperatures below 0 °C
without being connected to a battery and sufficiently
filled fuel cartridge (automatic antifreeze feature). Let
stand at room temperature for approx. 24 hours.
Please check battery voltage
(Error 50, 51, 52, 53)
Error 50: Battery voltage is too low (sense line).
Error 51: Battery voltage is too high (sense line).
Error 52: Battery voltage is too low (power line).
Error 53: Battery voltage is too high (power line).
Check connections and whether the battery is the
proper type.
Check battery voltage. If too low, use an external
battery charger to recharge.
Check other charging devices such as generators or
regulators for defects.
Automatic restart
(Error 63, 65)
Unit is restarting automatically.
Please check fuel cartridge
connection (Error 72)
Check connection and screw cartridge on tightly.