Operation
Page 90
En
gl
ish
the EFOY COMFORT switches off as soon as the battery reaches a voltage
of 14.2 V and the charging current drops below 2.0 A.
Permitted value ranges
for battery parameters
(Lead-acid, AGM, Gel)
Factory
defaults
Min.
Max.
User-de-
fined
value:
Switch-on delay
60 s
2 s
300 s
Switch-on voltage
12.3 V
11.0 V
13.0 V
Switch-off voltage
14.2 V
13.5 V
14.7 V
Switch-off current
-
80i
-
140i
-
210i
2.0 A
2.0 A
4.0 A
0.5 A
1.0 A
2.0 A
10.0 A
10.0 A
10.0 A
Absorption time
180 min
0 min
300 min
Max. charge time
24 h
2 h
120 h
Min. charge time
30 min
30 min
180 min
Altitude up to
1500 m
0 m
2000 m
Permitted value ranges
for battery parameters
(LiFePO4)
Factory
defaults
Min.
Max.
User-de-
fined
value:
Switch-on delay
60 s
2 s
300 s
Switch-on voltage
12,6 V
12.0 V
13.4 V
Switch-off voltage
14.5 V
13.8 V
14.6 V
Switch-off current
-
80i
-
140i
-
210i
2.0 A
2.0 A
4.0 A
0.5 A
1.0 A
2.0 A
10.0 A
10.0 A
10.0 A
Absorption time
180 min
0 min
300 min
Max. charge time
24 h
2 h
120 h