background image

 

SFC Energy AG 

Hints for external control of EFOY Pro fuel cell 

 

 

19.04.11, KS 

Hints for external control of EFOY Pro fuel cell 

 

The EFOY Pro fuel cell is capable to receive commands from an external controller. To use this 
functionality you can send serial commands or use switching contacts of “Data Interface”. To use external 
control functionality, EFOY Pro offers three possibilities: 

 

1) Button commands via serial communication 

Via serial communication (RS-232) the same commands triggered by the buttons of EFOY Pro’s remote 
control can be sent to the fuel cell. Three commands „Button On“, „Button Off“ and „Button Auto“ cover 
this functionality. The fuel cell reacts the same way as if these buttons are used on EFOY Pro’s remote 
control. Details for setting up serial communication are described in the manual for Interface Adapter. 

 

2) „Remote On“ Signal 

If EFOY Pro receives  „Remote On“ signal by switching contacts of serial communication it starts the 
charging cycle until switch off voltage is reached. In the display of the remote control you can see „R“ in the 
first line on the right as long as “Remote On” Signal is active. Is „Remote On“ Signal still active after a 
complete charging cycle, another charging cycle will start. Therefore we recommend to reset „Remote On“ 
signal after charging cycle has started. 

 

Switching contacts on data interface: 

 

 

Pin

Pin

Pin

Pin    

Function

Function

Function

Function    

1  DuoCartSwitch 

2  RxD (Data) 

3  TxD (Data) 

4  GND, Ground 

5  B 

6  Fuel Cartridge Sensor 

7  Remote On

Remote On

Remote On

Remote On    

8  Hybrid

Hybrid

Hybrid

Hybrid 

1

1

1

1    

8

8

8

8    