28/07/2020
VACUUM LEAK DETECTOR
VLXE .. Ex M and VLXE .. Ex MMV
- 21 -
(4) Hand-tighten union nut
(5) Wrench-tighten union nut until need for increased force is notice-
able (approx. 1 to 2 turns)
5.5 Electrical
Cables
The electrical connection lines should be resistant to the existing or
expected vapors and liquids.
Cross section of 1.0 mm
2
to 2.5 mm
2
Outer cable diameter of 5.5 to 13 mm. If other cable diameters are
used, the screw connections must be replaced, as
explosion protec-
tion depends on correct cable routing
.
5.6 Electrical Wiring Diagram
(1) Fixed wiring, i.e., no plug or switch connections.
(2) Observe the requirements for electric installations, if necessary,
also those of the electric companies.
(3) Terminal layout: (see also SL-854 310)
1/2
Power connection (100…240 V AC)
PE
Ground for the power connection
PA
Terminals for equipotential bonding
3/4
Occupied (vacuum pump)
5/6
External signal (may be used for internal buzzer).
7/8 Solenoid
valve
9/10
Probe contacts; the potential-free contacts of a leak de-
tection probe can be connected here.
11/12 Potential-free contacts (opened in case of alarm or loss
of power)
12/13 As above, but contacts closed
(17/18) Potential-free contacts, in parallel with pump running
(closed when pump is inactive and in case of loss of
power)
(18/19) As above, but contacts open
40/41 24 V DC as permanent power supply to power other as-
semblies or, for a device with a supply voltage of 24 V
DC, the power supply is connected here.
(4) Do not apply voltage until all electrical and pneumatic cables are
connected and the housing cover is closed.
Mounting
PA PA PA
Summary of Contents for VLXE Ex M Series
Page 49: ...28 07 2020 VACUUM LEAK DETECTOR VLXE Ex M and VLXE Ex MMV 49 12 7 Ex approval Appendix ...
Page 50: ...VACUUM LEAK DETECTOR VLXE Ex M and VLXE Ex MMV 28 07 2020 50 Appendix ...
Page 51: ...28 07 2020 VACUUM LEAK DETECTOR VLXE Ex M and VLXE Ex MMV 51 Appendix ...
Page 52: ...VACUUM LEAK DETECTOR VLXE Ex M and VLXE Ex MMV 28 07 2020 52 Appendix ...
Page 54: ...VACUUM LEAK DETECTOR VLXE Ex M and VLXE Ex MMV 28 07 2020 54 Appendix ...