10
Installation
GiottoSpot 400 rel.1.01
1.4 Lamp alignment
Every time a new lamp is installed in the fixture, it must be aligned with the optical system to ensure optimum even light output from the unit.
1. Install the new lamp (par. 1.3), close the fixture and switch it on
2. Connect the fixture to a lighting console.
3. Point the fixture at a flat surface (if possible white or light colored) at least three metres from the fixture.
4. Set the control channels to obtain a white beam. Then open the IRIS, set the DIMMER fully open, FOCUS correctly and do NOT
project GOBOS or COLORS.
6. Use screws 1, 2 and-3 to align the lamp until an evenly projected light beam is obtained, with no shadows or zones which are
brighter than others.
1.5 Installing /replacing gobos
Metal: After opening the fixture, locate the gobo to be replaced, press delicately downwards (Fig.1) until the spring and the gobo
come out, making sure they don't fall inside the fixture. Install the new gobo (1) as shown (Fig.2), followed by the locking spring
(2).
Dichro: After opening the fixture, locate the gobo to be replaced, press delicately downwards (Fig.1) until the spring, ring and the
gobo come out, making sure they don't fall inside the fixture. Install the new gobo (3) as shown (Fig.2), followed by the ring (4)
and the locking spring (5).
Fig.1
Fig 2
A: Color wheel
B: Effects wheel
C: Gobo wheel
1
2
3
4
5
ADJ
LAMP
AD
J
LA
M
P
A
D
J
LA
MP
1
2
3