L
AMP ALIGNMENT
When replacing the lamp with a new one, align the lamp with the optical system to obtain the max
uniformity and luminous performance by the projection.
1.
Install the new lamp close the fixture and switch it on
2.
Connect the fixture to a lighting console.
3.
Point the fixture at a flat surface (if possible white or light colored) at least three metres from
the fixture.
4.
Set the control channels to obtain a white beam. Then open the IRIS, set the DIMMER fully
open, FUOCO correctly and do not project GOBOS or COLORS.
5.
Use screws 1, 2 and-3 to align the lamp until an evenly projected light beam is obtained, with
no shadows or zones which are brighter than others.