SGM Technology for Lighting
GB
User’s Manual 1.00
Synthesis Wash 700
- 22 -
SHUTTER
COLOSE=EN
Enables shutter closure in the event of pan/tilt loss of position.
FACTORY=SET
Enables to set default parameters.
FACTORY
FACTORY=OFF
Value during normal operation.
PREVIOUS=SET
Enables to restore the values of the parameters set immediately
before FACT=SET procedure.
PREVIOUS
PREVIOUS=OFF PREV value during normal operation.
SETTING
-
Reserved Menu, access by password. Enable the calibration of
movement mechanical components (gobo wheels; color).
TEST=RESET
SET of the Fixture.
TEST=ALL
Run the test of all the effects in sequence.
TEST=PAN
Run PAN test.
TEST=TILT
Run TILT test.
TEST=IRIS
Run IRIS test.
TEST=COLOR
Run the color wheel test.
TEST=SHUTT
Shutter test.
TEST=DIMM
Dimmer test.
TEST=FROST
Frost test.
TEST=BLADE
Shaper Test
TEST=SHARP
Sharpness Test
TEST=ZOOM
Zoom test.
TEST=CYANO
Cyan wheel test.
TEST=MAGEN
Magenta wheel test.
TEST=YELLW
Yellow wheel test.
TEST
TEST=CTO
CTO test.
RESERVED
-
-
INPUT
°C
Shows the temperature of the imput board in centigrade
degrees.
INPUT
°F
Shows the temperature of the imput board in Fahrenheit
degrees.
PAN
°C
Shows the temperature of the the pan Control board in in
centigrade degrees.
PAN
°F
Shows the temperature of the the pan Control board in
Fahrenheit degrees.
TILT
°C
Shows the temperature of the the tilt Control board in
centigrade degrees.
TILT
°F
Shows the temperature of the the tilt Control board in
Fahrenheit degrees.
GOBO
°C
Shows the temperature of gobo module Control board in
centigrade degrees.
GOBO
°F
Shows the temperature of gobo module Control board in
Fahrenheit degrees.
ZOOM
°C
Shows the temperature of the zoom Control board in centigrade
degrees.
ZOOM
°F
Shows the temperature of the zoom Control board in Fahrenheit
degrees.
CMY
°C
Shows the temperature of the CMY Control board in centigrade
degrees.
CMY
°F
Shows the temperature of the CMY Control board in Fahrenheit
degrees.
HEAD
°C
Shows the temperature of the head fans Control in centigrade
degrees.
HEAD
°F
Shows the temperature of the head fans Control in Fahrenheit
degrees.
LAMP
°C
Shows the temperature of the Lamp heat sink Plate in
centigrade degrees.
LAMP
°F
Shows the temperature of the Lamp heat sink Plate in
Fahrenheit degrees.
BASE
°C
Shows the temperature of the Ballast board in centigrade
degrees.
BASE
°F
Shows the temperature of the Ballast board in Fahrenheit
degrees.
POWER
°C
Shows the temperature of the PFC board in centigrade degrees.
TEMPERATURE
POWER
°F
Shows the temperature of the PFC board in Fahrenheit degrees.