Calibration of the PAN and TILT “home” position and of the color
wheel “white” position
On the setting menu it is possibile to calibrate the PAN and TILT’s “home”
position and the color wheel’s ”white” starting position. To do the calibartion
please proceed as follows:
1.
Connect Synthesis Wash to the power supply, wait that the reset
operation are completed.
2.
Use the UP/DOWN keys to search the cercare il menu “SETTING”.
3.
Insert the access code to the SETTING’s sub-menu.
4.
Use the UP/DOWN keys to select the desired option (PAN, TILT,
COLOR) .
5.
Press “Enter” to select, the message on the display will start flashing.
6.
Regulate the offset by the UP/DOWN keys.
7.
Press ENTER to confirm (the message will stop flashing) and go back
to the SETTING’s sub-menu.
1.
Once performed all the calibrations, keep pressed the enter key for 4
seconds to go out from the setting menu.
Test functions
Test programs can be used in the event of it being necessary to check the
correct operation of the fixture or some of its parts.
To select the required test program, proceed as follows:
1.
Connect Synthesis to the power supply, wait till it has completed
reset operations.
2.
Use the UP/DOWN keys to find the “TEST” menu.
3.
Press ENTER for some seconds to confirm. The message on the
display will start to flash.
4.
Use UP/DOWN keys to select the program corresponding to the part
of the fixture to be tested.
5.
Press “Enter” to run the test program.
6.
Press Enter to quit the test functions, press Enter again a for few
seconds until “Test” re-appears on the display.
Reserved functions
Some fixture functions cannot be accessed by operators as they regard
software sections as yet to be defined in this firmware release. When
RESERVED appears on the display, you are in this section. Access is
forbidden.
TEST
TEST=RESET
RESERVED
SETTING
PAN=0
TILT=0
COLOR=0