GB
SGM Technology for Lighting
Synthesis Wash 700
User’s Manual 1.00
- 7 -
1.3
Electrical Specifications
DANGER!!
1 CLASS FIXTURE, GROUND NEEDED!
POWER REQUIREMENTS:
Univesal 90V-245 V 50Hz,60Hz.
POWER ABSORBED:
1000W@230V 50Hz
PROTECTION FUSES:
2x16 Amp
ADDITIONAL ELECTRONICAL PROTECTIONS
:
In addiction to the tradictional electrical fuse protection, Synthesis is fitted with sophisticated
electronical systems able to protect the fixture from overvoltage or dangerous low voltage, avoiding,
in this way, damages to the electronic boards as usually happens in these kind of situations. The
electronic ballast fitted as standard, allows a wide possibility to use the fixture with any power
supply included between 90-240 Volts 50 or 60 Hz, exposing anyway Synthesis to the more common
risks in the electrical installations on mondial level (neutral detachment or fluctuating low voltage).
For this reason SGM has developed a system able to protect Synthesis from the common problems of
the electrical installation, making everything transparent to the end user. The protections are:
1.
Protections against the overvoltage.
In case of power supply over 280 Vrms, due to the neutral detachment, the internal protection detects
the overvoltage preventing the fixture’s switching on. The display, powered by the internal battrey, will
show the error message "POWER OVERVOLTAGE"
2.
Protections against the low voltage.
This second case involves all those countries where the power supply is 100-120Volts. In this
second case we can meet two different situations:
In the first situation, we have a fixture already powered at 100 Volts and, for some reasons,
the power supply lowers under 80 Volts. In this case, Synthesis detects the low voltage but
keeps on working normally. If this situation lasts for a long time, then the internal
temperatures will increase until the temperature protections won’t stop the internal
powering.
In the second situation, Synthesis is not yet powered and, by swithcing on the fixture, it
immediately detects that the voltage is already under 80 Volts. In this case, the internal
protection will provide to lock the fixture immediately.
www.audiovias.com
Summary of Contents for Synthesis Wash 700
Page 47: ...www audiovias com...