background image

PAGE 7

PAGE 6

DISCONNECT THE AIR COMPRESSOR:

 Always disconnect the air 

compressor from the mains power supply and decompress before 
performing maintenance, changing any parts and when not in use.

MAINS POWER CABLE PRECAUTIONS: 

Never pull on the cable 

when removing the plug from the mains socket, or lift the compressor 
by the mains cable.

AVOID UNINTENTIONAL STARTING: 

When connecting the air com-

pressor to the mains supply make sure the red button on top of the 
air compressor is in the OFF position. 

STORE THE AIR COMPRESSOR PROPERLY: 

When not in use the air 

compressor should be stored in a secure, dry place out of the reach 
of children. Always lock up the storage area.

MAINTAIN THE AIR COMPRESSOR WITH CARE: 

If the air  

compressor is damaged in any way, have it repaired by a qualified 
engineer.

DO NOT USE EXTENSION LEADS:

 Using extension leads can cause 

your compressor motor to burn out. Only use extension hoses. 

DISPOSAL INFORMATION:

 The air compressor should be disposed 

of in a safe and environmentally friendly manner. Contact your local 
Council for disposal assistance.

DO NOT WELD TO THE PRESSURE VESSEL:

 Do not weld or 

modify the pressure vessel in any manner. 

Before you connect the equipment to the mains supply make sure 
that the data on the rating plate are identical to the mains data:

• Check the equipment for damage which may have occurred in
transit.
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or wet room.
• The compressor may only be used in suitable rooms (with good
ventilation and an ambient temperature from +5 °C to 40 °C). There
must be no dust, acids, vapors, explosive gases or inflammable
gases in the room.
• The compressor is designed to be used in dry rooms. It is prohib-
ited to use the compressor in areas where work is conducted with
sprayed water.

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS

WWW.SGS-ENGINEERING.COM

Summary of Contents for SC50VT

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SC50VT AIR COMPRESSOR...

Page 2: ...pply before main tenance or removing any covers Do not use in a damp environment Risk of accidental start up The compressor could start automatically in the event of a power cut and subsequent reset D...

Page 3: ...sed KEEP THE WORK AREA CLEAN Cluttered areas mean accidents so clear the work area of all unnecessary tools debris and furniture SAFETY PRECAUTIONS Take environmental influences into account Do not ex...

Page 4: ...n leads can cause your compressor motor to burn out Only use extension hoses DISPOSAL INFORMATION The air compressor should be disposed of in a safe and environmentally friendly manner Contact your lo...

Page 5: ...e PREPARATION FOR STARTING GENERAL MAINTENANCE To ensure a long service life of the pressure tank drain off the condensed water by opening the drain valve each time after using Release the tank pressu...

Page 6: ...r needs to be stopped set the power switch to the OFF position 6 Release the excess pressure by switching off the compressor and using the compressed air which is still left in the air tank e g with a...

Page 7: ...NTENANCE TROUBLESHOOTING PROBLEM POSSIBLE CAUSE ACTION Motor unable to run running slow or getting hot 1 Fault in line or insufficient voltage 2 Power wire too thin or long 3 Fault in pressure switch...

Page 8: ...cuts out this is a safety feature to protect you and your compressor Leave this compressor for a good while until you reset it If the compressor turns off again on reset you should not keep running it...

Page 9: ...8 Flat gasket 2 905120 25 Hand shank 1 905085 69 Bolt M4 2 905121 26 Plastic gasket 1 905086 27 Elbow joint 1 905087 28 Socket head cap screw 1 905049 29 Axle 1 905088 30 Flat gasket 1 905089 31 Wheel...