background image

PAGE 8

PAGE 9

ASSEMBLY

1. Set the compressor on a clean, flat surface in a ventilated space.

2. Before you use the machine, make sure that the mains voltage is within ±5%

of rated voltage (see the rating plate).

3. Plug the compressor in and press the power button to the ON position.

4. Use the pressure regulator to set the air pressure output.

5. The set pressure can be drawn from the quicklock coupling.

6. The tank pressure can be read off the pressure gauge.

• You must fully assemble the appliance before using it for the first time!
• Fit the supplied wheels, rubber feet and handle.
• The compressor is equipped with a mains cable with shock-proof plug.
This can be connected to any 230V ~ 50 Hz socket which is protected by a 16 A
fuse.

PREPARATION FOR STARTING

GENERAL MAINTENANCE

To ensure a long service life of the pressure tank, drain off the condensed 
water by opening the drain valve each time after using. Release the 
tank pressure first. Open the drain screw by turning counter-clockwise 
(looking at the screw from the bottom of the compressor) so that all the 
condensed water can escape the tank. Then close the drain screw (turn it 
clockwise). Check the air tank for signs of rust and damage each time 
before using. Do not use the compressor with a damaged or rusty air tank. 

Dispose of the condensed water in an environmentally compatible manner 
at a suitable collection point.

The safety valve has been set for the highest permitted pressure of the air 
tank. It is prohibited to adjust the safety valve or remove its seal. Actuate 
the safety valve from time to time to ensure that it works when required. 

WWW.SGS-ENGINEERING.COM

WWW.SGS-ENGINEERING.COM

Summary of Contents for SC50VT

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SC50VT AIR COMPRESSOR...

Page 2: ...pply before main tenance or removing any covers Do not use in a damp environment Risk of accidental start up The compressor could start automatically in the event of a power cut and subsequent reset D...

Page 3: ...sed KEEP THE WORK AREA CLEAN Cluttered areas mean accidents so clear the work area of all unnecessary tools debris and furniture SAFETY PRECAUTIONS Take environmental influences into account Do not ex...

Page 4: ...n leads can cause your compressor motor to burn out Only use extension hoses DISPOSAL INFORMATION The air compressor should be disposed of in a safe and environmentally friendly manner Contact your lo...

Page 5: ...e PREPARATION FOR STARTING GENERAL MAINTENANCE To ensure a long service life of the pressure tank drain off the condensed water by opening the drain valve each time after using Release the tank pressu...

Page 6: ...r needs to be stopped set the power switch to the OFF position 6 Release the excess pressure by switching off the compressor and using the compressed air which is still left in the air tank e g with a...

Page 7: ...NTENANCE TROUBLESHOOTING PROBLEM POSSIBLE CAUSE ACTION Motor unable to run running slow or getting hot 1 Fault in line or insufficient voltage 2 Power wire too thin or long 3 Fault in pressure switch...

Page 8: ...cuts out this is a safety feature to protect you and your compressor Leave this compressor for a good while until you reset it If the compressor turns off again on reset you should not keep running it...

Page 9: ...8 Flat gasket 2 905120 25 Hand shank 1 905085 69 Bolt M4 2 905121 26 Plastic gasket 1 905086 27 Elbow joint 1 905087 28 Socket head cap screw 1 905049 29 Axle 1 905088 30 Flat gasket 1 905089 31 Wheel...