AVOID UNINTENTIONAL STARTING: 

When connecting the air compres-

sor to the mains supply make sure the red button on top of the air com-
pressor is in the OFF (down) position. 

STORE THE AIR COMPRESSOR PROPERLY: 

When not in use the air com-

pressor should be stored in a secure, dry place out of the reach of children. 
Always lock up the storage area.

MAINTAIN THE AIR COMPRESSOR WITH CARE: 

If the air compressor is 

damaged in any way, have it repaired by a qualified engineer.

DO NOT USE EXTENSION LEADS:

 Using extension leads can cause your 

compressor motor to burn out. Only use extension hoses. 

DISPOSAL INFORMATION:

 The air compressor should be disposed of in 

a safe an environmentally friendly manner. Contact your local Council for 
disposal assistance.

DO NOT WELD TO THE PRESSURE VESSEL:

 Do not weld or modify the 

pressure vessel in any manner. 

SAFETY PRECAUTIONS

ASSEMBLY

1.  Remove the travel plug

2.  Attach the air filter, tightening 

hand tight only

3.  Remove the travel plug

4.  Fit the breather plug

WWW.SGS-ENGINEERING.COM

Summary of Contents for SC8H

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SC8H AIR COMPRESSOR...

Page 2: ...t be disconnected from the mains supply before maintenance or removing any covers Do not use in a damp environment Risk of accidental start up The compressor could start automatically in the event of...

Page 3: ...hments and ensure that any people in the work area are suitably dressed KEEP THE WORK AREA CLEAN Cluttered areas mean accidents so clear the work area of all unnecessary tools debris and furniture SAF...

Page 4: ...or is damaged in any way have it repaired by a qualified engineer DO NOT USE EXTENSION LEADS Using extension leads can cause your compressor motor to burn out Only use extension hoses DISPOSAL INFORMA...

Page 5: ...not remove the breather plug and fill with compressor oil our part code SO2068 OPERATION 1 Attach a hose to the quick re lease coupler on the compres sor and to an air tool 2 Turn the compressor on b...

Page 6: ...surise the air hose 3 Disconnect the tool from the hose 4 Open the drain cock to remove any condensation from the compressor 3 Set the regulator to the correct pressure for the air tool check in the...

Page 7: ...ADJUSTMENT THERMAL RESET SWITCH This compressor has a thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal ove...

Page 8: ...Check the oil level after every 20 working hours and replenish if necessary CAUTIONS MAINTENANCE CLEAN THE AIR FILTERS MONTHLY The air filters must be examined monthly and more often in dusty conditio...

Page 9: ...8 48 Tooth washer 8 2 904981 15 Piston 42 1 904949 49 Nut M8 2 901995 16 Circlip 14 2 904950 50 Air filter 1 904983 17 Piston pin 12x39 5 1 904951 51 Handle 1 904984 18 Connecting rod 1 904952 52 Disc...

Page 10: ...dy in the main compressor 3 Piston knocking the valve seat 4 Moving parts seriously worn 1 Check and retighten 2 Check and clean away 3 Replace with thicker paper gasket 4 Repair or replace Pressure i...

Page 11: ...cretary Derby UK 24th March 2019 SGS Engineering UK Ltd SGS Engineering UK Ltd West Side Park Raynesway Derby DE21 7AZ Air Compressor SC8H 2014 30 EU Electromagnetic Compatibility Directive 2006 42 EC...