PAGE 13

PAGE 12

STARTING

1.  Turn the main AC switch to the ‘OFF’ position.

2.  Make sure that the machine has fuel for the task.

3.  Make sure the emergency STOP switch is out (turn anti-clockwise).

4.  Set the engine speed lever is set to ‘RUN’.

5.  Turn the starting key clockwise to the ‘START’ position. Remove your 

hand from the key as soon as the engine starts.

6.  If the engine does not start after 10 seconds, wait 15 seconds before 

trying again. Excessive start attempts will cause the battery to flatten.

7.  If it does not start after 3 attempts, or runs intermittently with excessive 

smoke check that the fuel system is fully primed.

8.  Always leave the key in the ‘ON’ position whilst the engine is running.

9.  Run machine for two minutes before applying load

10.  Insert the plug into the socket you are about to use.

11.  Turn the main AC switch to the ‘ON’ position and turn the electrical 

appliance ‘ON’.

Checks before use

1.  Any abnormal sound or vibration?
2.  Is the engine misfiring or running rough?
3.  What about the color of the exhaust gas? (ls it black or too white?). If 

you notice any situation mentioned above, please contact SGS. 

PRIMING THE GENERATOR

Before starting to prime make sure that there is fuel in tank and that you 
can contain any fuel spilt.

1.  Release the pipe clip on the diesel fuel line connected to the injector 

pump. Make sure you pinch the fuel line and then release slowly until 
all air is released and fuel appears.

2.  When fuel appears replace pipe onto the injector pump and replace 

clip. Clear up any fuel spills before restarting.

3.  The above may be necessary when new, or if the machine runs out of 

fuel.

WWW.SGS-ENGINEERING.COM

Summary of Contents for SDG8000SELR

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL DIESEL GENERATOR...

Page 2: ...d posi tions of the controls and indicators TECHNICAL SPECIFICATION Model SDG8000SELR Type Single phase alternating current Excitation System Controllable silicon Voltage Adjustment Automatic Voltage...

Page 3: ...lexible cable in accordance with IEC245 4 or the equivalent should be used When using extension lines or mobile distribution networks the total length of lines for a cross section of 1 5mm2 should not...

Page 4: ...oo much oil to the engine because a sudden in crease in engine rpm could be caused by its combustion Always check the oil level before starting the engine and refill if necessary Use proper oil to pre...

Page 5: ...mend ed oil API CH 4 CF SJ SL diesel engine oil or higher grade BATTERY When you first install the battery ensure that the battery s polarity is the same as the generator s battery leads Black negativ...

Page 6: ...ment 3 Clean the air filter 4 Reattach the air filter cover and screw on the nut RUNNING IN THE ENGINE The first 20 hours are the break in period of the engine For this reason it is important to follo...

Page 7: ...inutes before applying load 10 Insert the plug into the socket you are about to use 11 Turn the main AC switch to the ON position and turn the electrical appliance ON Checks before use 1 Any abnormal...

Page 8: ...start The governer lever is not at START position Set lever to START position Emergency STOP button activated depressed Re set emergency STOP but ton Insufficient fuel Refill with fuel Fuel injection...

Page 9: ...03640 46 Fuel return pipe 903669 14 Spring washer 5 1 903641 47 Oil filter 904806 15 Flat gasket 5 5 10 903642 48 Big cushion ring 6X18 903671 16 M5X20 Flange Bolt 903643 49 Silent canopy assembly 903...

Page 10: ...s and Standard s PLACE DATE Signature Robert Wyatt Company Secretary Derby UK 08th NOV 2018 SGS Engineering UK Ltd Diesel Generator SDG8000SELR 2004 108 EC Electromagnetic Compatibility Directive 2006...

Reviews: