53
6.2 Under Normal Condition
6.2.1 Turn off the AC breaker and unplug all the loads (Figure 34)
6.2.2 Run the unit for several minutes without load to cool down the generator set.
6.2.3 Set the ignition switch to OFF position(Figure 35)
6.2.4 Set the fuel switch to OFF position
(Figure 36)
WARNING Don’t touch the heating
components before the
unit cools down after
stopping the engine to
avoid burns.
CAUTION Fuel storage in unit which is not to be used for long time will cause it
difficult to start the engine. Drain the fuel for long-time storage of the
unit.
7 Maintenance
7.1 Maintenance Schedule: The Unit should be serviced according to the following
Maintenance Schedule:
Period
Item
Each
Time
20 Hrs or
1st Month
50Hrs or Every
3 Month
100Hrs or every 6
Month
300Hrs or every one
year
Check engine oil
Check
Replace engine oil
Replace
Replace
Check air cleaner
Check
Wash air cleaner
Clean
Oil filter cover
Clean
Battery electrolyte
level
Check
Spark plug
Clean
Valve clearance
Check & readjust
Wash cylinder
cover
Clean
Wash fuel tank
Replace every 3 years