engine oil, pull the recoil start slowly to distribute the oil evenly.
9.2.4 Pull up the recoil start handle slowly until an anti-action is felt, keep pulling until
over passing the resistance. At this position, the inlet and outlet valves of the engine
are closed so as to prevent the rusty crankcase.
10. Troubleshooting
10.1 Failure to Start the Engine: the generator cannot be started. (Figure 52)
10.1.1 Check if the ignition switch is at ON position. (Figure 53)
10.1.2 Check if the engine oil level is too low. (Figure 54)
Figure 54
10.1.3 Check the fuel inside the tank. (Figure 55)
10.1.4 Remove the spark plug, check if there is spark jumping
out. (Figure 56)
10.1.5 If the generator set still can not be started after the
above steps, consult your dealer for help.
(Figure 57)
10.2 Failure to Generate Power: the unit doesn’t generate electricity when the
engine is running.
10.2.1 Check the lamps (Figure 58)