SAFETY NOTICE
Many electrical and mechanical parts in television
receivers have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage and etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified by "
å
"
and shaded areas in the Replacement Parts Lists and
Schematic Diagrams.
IMPORTANT SERVICE SAFETY PRECAUTION
(Continued)
1. Inspect all lead dress to make certain that leads are
not pinched or that hardware is not lodged between
the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators and etc.
3. To be sure that no shock hazard exists, check for
leakage current in the following manner.
»
Plug the AC cord directly into a 120 volt AC outlet,
(Do not use an isolation transformer for this test).
»
Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15mF capacitor in series
with all exposed metal cabinet parts and a known
earth ground, such as electrical conduit or electrical
ground connected to earth ground.
»
Use an AC voltmeter having with 5000 ohm per volt,
or higher, sensitivity to measure the AC voltage drop
across the resistor.
For continued protection, replacement parts must be
identical to those used in the original circuit. The use of
substitute replacement parts which do not have the same
safety characteristics as the factory recommended
replacement parts shown in this service manual, may
create shock, fire, X-radiation or other hazards.
BEFORE RETURNING THE RECEIVER
(Fire & Shock Hazard)
Before returning the receiver to the user, perform
the following safety checks.
»
Connect the resistor connection to all exposed metal
parts having a return to the chassis (antenna, metal
cabinet, screw heads, knobs and control shafts,
escutcheon and etc.) and measure the AC voltage
drop across the resistor.
AII checks must be repeated with the AC ine cord
plug connection reversed. (If necessary, a non-
polarized adapter plug must be used only for the
purpose of completing these check.)
Any current measured must not exceed 0.5 milliamp.
Any measurements not within the limits outlined
above indicate of a potential shock hazard and
corrective action must be taken before returning the
instrument to the customer.
1.5k ohm
10W
0.15
µ
F
TEST PROBE
CONNECT TO
KNOWN EARTH
GROUND
TO EXPOSED
METAL PARTS
20MU11
Summary of Contents for 20MU11
Page 4: ...4 LOCATION OF USER S CONTROL 20MU11 ...
Page 10: ...10 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT Ë 20MU11 PWB B PWB A PWB B 20MU11 ...
Page 11: ...11 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM 20MU11 ...
Page 13: ...6 5 4 3 2 1 A B C D E F G H 20MU11 SCHEMATIC DIAGRAM CRT UNIT DUNTK9533WEV4 DUNTK9530WEW6 13 ...
Page 14: ...14 20MU11 ...
Page 15: ...15 20MU11 ...
Page 16: ...16 20MU11 ...
Page 17: ...20MU11 17 ...
Page 19: ...19 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side 20MU11 ...
Page 21: ...21 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side 20MU11 ...