2T-C45AE1X
5 – 6
6.
WRITING PANEL SIZE
i.
Enter the adjustment process mode [ PAGE 2/13 (INIT) ]
ii.
Point the cursor to [PANEL SETTING]
iii.
Select Panel Size and press [enter] key
02/11 [INIT]
FACTORY INIT
General
PANEL SETTING
PANEL_45_INNOLUX
PUBLIC MODE
OFF
OPERATION ACUTIME
xxxxH xxM
RESET OFF
7. POWER
CONSUMPTION
Power Consumption Measurement Method
①
Aging time : minimum 30 minutes
②
Signal
:
Color
Bar
③
Audio frequency : 400 Hz
④
AV Mode : Dynamic
⑤
Picture Setting : Backlight/ Brightness/ Contrast : MAX;
⑥
Audio Output (400 Hz) : 1/8 of Maximum Audio Output (10W + 10W) ;
VOL =
19
⑦
AC Input: 99VAC ~ 264VAC 50Hz
⑧
Wake UP LAN : Off
Model
2T-C45AE1X
Power Consumption Specification
(IEC600657)
Standard Value
Limit Value
Power Consumption
82
W
+10%
Power Consumption at Stand-by
Operating
0.45
W
0.3W ~ 0.6W
8.
CHECKER PROCESS
i.
Function Check : Main PWB inspection/functional check
ii. K-MODE
Color
Indication
-The default condition for K-Mode is Magenta colour.
-
Because of this model donʼt have HD comp
onent adjusment, Checker need to
be set to send the command(RSWR0201) to change the colour of K-Mode
from Magenta to Yellow.