background image

1

AY-XP07ER–AE-X07ER
AY-XP09ER–AE-X09ER
AY-XP12ER–AE-X12ER

S////AYXP07ER

SERVICE MANUAL

MODEL

SHARP CORPORATION

TABLE OF CONTENTS

Page

SPECIFICATIONS .............................................................................................................................................. 2
EXTERNAL DIMENSIONS ................................................................................................................................. 3
WIRING DIAGRAMS .......................................................................................................................................... 4
ELECTRICAL PARTS ......................................................................................................................................... 5
REFRIGERATION  CYCLE ................................................................................................................................ 6
PERFORMANCE CURVES ................................................................................................................................ 7
REPLACEMENT PARTS LIST
  AY-XP07ER / AY-XP09ER / AY-XP12ER ......................................................................................................... 8
  AE-X07ER / AE-X09ER / AE-X12ER .............................................................................................................. 11

(INOOR UNIT)

(OUTDOOR UNIT)

INDOOR UNIT

AY-XP07ER
AY-XP09ER
AY-XP12ER

OUTDOOR UNIT

AE-X07ER
AE-X09ER
AE-X12ER

SPLIT TYPE

ROOM AIR CONDITIONERS

In the interests of user-safety (Required by safety regulations
in some countries)  the set should be restored to its original
condition and only parts identical to those specified should be
used.

MODELS

Summary of Contents for AE-X07ER

Page 1: ...MANCE CURVES 7 REPLACEMENT PARTS LIST AY XP07ER AY XP09ER AY XP12ER 8 AE X07ER AE X09ER AE X12ER 11 INOOR UNIT OUTDOOR UNIT INDOOR UNIT AY XP07ER AY XP09ER AY XP12ER OUTDOOR UNIT AE X07ER AE X09ER AE X12ER SPLIT TYPE ROOM AIR CONDITIONERS In the interests of user safety Required by safety regulations in some countries the set should be restored to its original condition and only parts identical to...

Page 2: ...or Freol Alphc 68M Evaporator Louver Fin and Grooved tube type Refrigerant system Condenser Corrugate Fin and Grooved tube type Control Expansion valve Refrigerant R410A 1000g 1000g 1080g De lce system Micro computer controled reversed systems Noise level High dB A 38 46 43 48 45 49 at cooling Low dB A 32 34 38 Soft dB A 26 28 31 Fan system Drive Direct drive Air flow quantity High m3 min 7 8 22 9...

Page 3: ...SIONS 22 0 58 18 5 175 CRMC A442JBE0 R03 AAA 2PCS SHARP CORPORATION INVERTER AIR CONDITIONER 790 240 285 810 Figure E 1 INDOOR UNIT C 165 167 5 136 81 B 72 540 299 324 A 12 37 5 ø 4 5 58 135 14 B 730 780 A 515 540 AE X07ER AE X09ER AE X12ER C 250 265 Figure E 2 OUTDOOR UNIT ...

Page 4: ...NIT CONTROL BOARD UNIT SERIAL SIGNAL CIRCUIT EVAPORATOR LED INDICATION FOR SELF DIAGNOSIS Abnormal contents Temperature Indicator Blinking No 1 2 5 6 7 9 11 13 14 17 18 Short circuit of the Thermistor Overheat error compressor and cycle Open circuit of the Thermistor Abnormal DC current Abnormal AC current Abnormal outdoor fan motor Abnormal Thermistor or four way valv Abnormal PAM voltage and PAM...

Page 5: ...nsformer FUSE1 QFS GA052JBZZ 250V 3 15A FUSE2 QFS GA051JBZZ 250V 2A For Model AE X07ER AE X09ER AE X12ER DESCRIPTION MODEL REMARKS Compressor 5RS092XDF D C brush less motor Outdoor fan motor ML A902 DC Motor Outdoor fan motor capacitor WPE1 QFS GA050JBZZ 250V 1A WPE101 QFS GA051JBE0 250V 2A WPE3 QFS GA052JBZZ 250V 3 15A WPE5 QFS GA065JBZZ 400V 20A QFS GA066JBZZ 400V 15A ELECTRICAL PARTS ...

Page 6: ... valve 2 way valve Silencer Coil Expansion valve Flow for Refrigerant for AY XP07ER AY XP09ER Flow for Refrigerant for AY XP12ER AY XP07ER AY XP09ER Indoor side Standard conditions Dry bulb Temp C Relative Humidity 20 Heating Outdoor side Dry bulb Temp C Relative Humidity 7 87 27 Cooling 47 35 40 AY XP07ER AY XP09ER AY XP12ER Temperature at each part and pressure in 3 way valve NO Condition Coolin...

Page 7: ... temp C Input W Figure P 1 At Cooling for AY XP07ER Figure P 2 At Heating for AY XP07ER 25 30 35 40 2 4 2 6 2 8 3 0 3 2 500 600 700 800 Cooling capacity kW Outside air temp C Input W 5 0 5 7 10 3 0 2 5 3 5 4 0 700 800 900 1000 Heating capacity kW Outside air temp C Input W Figure P 3 At Cooling for AY XP09ER Figure P 4 At Heating for AY XP09ER 25 30 35 40 3 2 3 4 3 6 3 8 4 0 800 900 1000 1100 Cool...

Page 8: ...1JBFA Cover hinge 1 AC 2 8 3 PCOV B005JBFA Louver cover 1 AF 2 9 PCOV A849JBFZ Side cover 1 AF 2 10 PGID A109JBFZ Guide 2 AF 2 11 CLOV A054JBKZ Direct louver ass y 1 AN 2 11 1 MLOV A385JBFA Air direction louver 1 2 11 2 NBRG A030JBFA Bearing 1 AB 2 11 3 NBRG A037JBFA Bearing 1 AE 2 12 CPNL A485JBKZ Cont box cover ass y 1 AQ 2 13 FCOV A143JBFZ Senser cover 1 AD 2 14 PCOV A992JBFZ Led holder 1 AD 2 ...

Page 9: ...badge AYXP12ER 1 AC CYCLE PARTS 3 1 CPIPCA796JBKZ Inlet tube ass y AYXP07ER AYXP09ER 1 AX 3 1 CPIPCA813JBKZ Inlet tube ass y AYXP12ER 1 3 2 DEVA A189JBKZ Evaporator ass y 1 BS 3 3 LX NZA169JBE0 Flare nut1 4 1 AG 3 4 PCAP A064JBE0 Cap 1 4 1 ACCESSORY PARTS 4 1 CFIL A088JBKZ Purify filter ass y 1 AR 4 2 CRMC A629JBEZ Remote control 1 BB 4 3 FFZK A178JBKZ Screws kit 1 4 4 LHLD A688JBFA Cord holder 1 ...

Page 10: ...マー 4 10 1 11 2 17 2 13 2 20 2 25 2 29 2 23 2 26 2 16 2 19 2 18 2 12 2 10 4 3 4 2 4 5 4 9 2 9 2 5 2 4 3 1 1 7 1 3 1 2 1 6 1 5 1 1 2 3 1 4 2 7 2 6 2 1 2 8 1 8 1 9 4 4 2 2 3 4 3 3 3 2 4 7 4 8 4 1 2 21 4 2 21 2 21 3 2 11 90 1 90 2 90 3 2 28 2 24 2 14 2 15 2 27 1 10 2 22 2 27 2 11 3 2 20 7 2 20 6 2 20 3 2 20 1 2 22 1 2 22 2 2 20 5 2 20 9 2 20 2 2 20 8 2 20 4 2 11 1 2 11 2 2 8 1 2 8 3 2 8 2 2 20 14 2 20...

Page 11: ... 1 AC 2 4 LX BZA261JBEZ Special screw 4 AC 2 5 PCOV A881JBFA Reactor cover AEX07ER AEX09ER 1 AL 2 6 LANG A504JBYZ Reactor angle AEX12ER 1 AP 2 7 CFTA A268JBKZ Cover 1 AN 2 7 1 PCOV A594JBPZ Terminal cover 1 AE 2 7 2 PFTA A090JBFA Cover 1 AL 2 8 PRDAFA170JBEZ Heat sink 1 AR 2 9 FDAI A006JBWZ Capacitor angle assy 1 AG 2 10 LBNDKA105JBWZ Capacitor clamp 1 AD 2 11 PBOX A396JBFZ Control box 1 AP 2 12 P...

Page 12: ...1 AQ 3 6 LX NZA271JBEZ Bonnet 1 3 7 DVLV A581JBKZ Control valve ass y AEX07ER AEX09ER 1 BG 3 7 DVLV A653JBKZ Control valve ass y AEX12ER 1 3 8 CCIL A129JBKZ Coil ass y 1 AU 3 9 PVLVXA052JBEZ Reverse valve AEX07ER AEX09ER 1 BB 3 9 PVLVXA061JBEZ Reverse valve AEX12ER 1 BD 3 10 PDAI A123JBTA Flare coupling base 1 3 11 PGUM A008JBE0 Damper rubber 1 AF 3 12 DCON A242JBPZ Condenser ass y AEX07ER AEX09ER...

Page 13: ...2 33 2 18 2 21 1 11 3 11 2 19 2 31 2 26 3 12 1 10 3 11 3 12 2 27 3 15 3 14 3 13 3 10 2 28 2 20 2 7 1 2 7 2 2 30 2 25 2 13 2 14 2 10 2 1 2 8 1 4 1 5 3 7 3 8 3 9 3 5 3 1 2 5 1 4 1 4 2 32 2 15 2 16 2 6 3 2 3 3 3 4 3 4 2 4 2 4 1 7 1 3 1 6 2 9 1 1 1 2 2 2 2 3 2 7 1 8 1 9 AE X12ER AE X12ER AE X07ER AE X09ER AE X07ER AE X09ER ...

Page 14: ...14 AY XP07ER AE X07ER AY XP09ER AE X09ER AY XP12ER AE X12ER MEMO ...

Page 15: ...15 AY XP07ER AE X07ER AY XP09ER AE X09ER AY XP12ER AE X12ER MEMO ...

Page 16: ...16 AY XP07ER AE X07ER AY XP09ER AE X09ER AY XP12ER AE X12ER 2004 13 SHARP CORP ...