background image

67

8

(B) Open the SPF/RSPF and rotate the roller rotating knob to remove the 

misfed original from the exit area. If the misfed original cannot be easily 
removed, proceed to (C).

(AL-1551CS)

With the RSPF, pull out the reversing tray to remove the misfed original.

(C) If the original does not move easily into the exit area, remove it in the 

direction of the arrow while rotating the knob.

With the RSPF, after removing the misfed original from the exit area, 
be sure to insert the reversing tray into the exit area until it locks in 
place.

A number may appear in the display after a minus sign, indicating the 
number of the originals that must be returned to the original feeder tray. 
Open and close the SPF/RSPF to clear the SPF/RSPF misfeed (

indicator, and then return the required number of originals. Then press 
the start (

) key to resume copying.

Roller rotating knob

Reversing tray

AL-1215_1530-1551CS.book  67 

ページ

  

2002年8月7日 水曜日 午前9時34分

Summary of Contents for AL-1530

Page 1: ...NUAL Page INTRODUCTION SETTING UP THE UNIT LOADING PAPER MAKING COPIES SPECIAL FUNCTIONS MAINTENANCE TROUBLESHOOTING THE UNIT 4 7 14 46 52 57 61 68 INSTALLING THE SOFTWARE 19 APPENDIX AL 1215 AL 1530CS AL 1540CS AL 1551CS MODEL AL 1551CS AL 1540CS AL 1215 AL 1530CS ...

Page 2: ...re reference MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Address City State Zip Telephone Service Station Address City State Zip Telephone To obtain service or to obtain product literature accessories or supplies please call 1 630 378 3590 in the USA or 905 568 7140 in Canada For customer assistance please visit http www sharp usa com for USA or http www sharp ca for Canada on the World Wid...

Page 3: ...cutive holidays turn the power switch off and remove the power cord from the outlet When moving the unit be sure to turn the power switch off and remove the power cord from the outlet Do not cover the unit with a dust cover cloth or plastic film while the power is on Doing so may prevent heat radiation damaging the unit Use of controls or adjustments or performance of procedures other than those s...

Page 4: ...of Adobe Systems Incorporated All other trademarks and copyrights are the property of their respective owners As an ENERGY STAR Partner SHARP has determined that this product meets the ENERGY STAR guidelines for energy efficiency Safety precautions This Digital Copier is rated Class 1 and complies with 21 CFR 1040 10 and 1040 11 of the CDRH standards This means that the unit does not produce hazar...

Page 5: ...R MODE 32 USING THE SCANNER MODE 34 HOW TO USE THE ONLINE MANUAL 43 USING OTHER INSTALLED DRIVERS 44 CONNECTING THE INTERFACE CABLE 45 5 MAKING COPIES COPY FLOW 46 ORIGINAL PLACEMENT 47 SET THE COPY QUANTITY 49 EXPOSURE ADJUSTMENT PHOTO COPYING 49 REDUCTION ENLARGEMENT ZOOM 51 6 SPECIAL FUNCTIONS ABOUT THE SPECIAL FUNCTIONS OF AL 1551CS 52 DESCRIPTION OF SPECIAL FUNCTIONS 54 TONER SAVE MODE 54 USE...

Page 6: ...on how to solve driver or software problems Conventions used in this manual and online manual This operation manual explains the operation of the AL 1215 AL 1530CS AL 1540CS and AL 1551CS models In cases where the operation is the same the AL 1551CS is used Illustrations of driver screens and other computer screens show the screens that appear in Windows XP Home Edition Some of the names that appe...

Page 7: ...SB interface Parallel interface Multi bypass tray AL 1551CS Paper tray 2 Original guide Original feeder tray Feeding roller cover 5 3 12 Original table Operation panel Front cover Paper tray Side cover Side cover open button Bypass paper guides Paper output tray 1 2 3 4 5 6 7 8 Paper output tray extension Power switch Handle Power cord Fusing unit release lever Transfer charger Charger cleaner 9 1...

Page 8: ...y a lit indicator p 51 Copy ratio display key p 51 1 2 3 4 5 6 7 8 Display Displays the specified copy quantity zoom copy ratio user program code and error code SCANNER key and indicator p 31 p 39 AL 1530CS AL 1540CS AL 1551CS ONLINE key and indicator AL 1530CS AL 1540CS AL 1551CS Lights up when the unit is used as a printer and scanner For description of the ONLINE indicator see INDICATORS ON THE...

Page 9: ...or use or if a function cannot be used see TROUBLESHOOTING THE UNIT p 61 1 Open the package and make sure that all the accessories are supplied with the unit p 8 2 Remove the protective materials p 9 8 Now you can copy p 46 print p 33 or scan p 34 your document 3 Install the TD cartridge p 10 4 Load the paper in the paper tray p 15 or the multi bypass tray 2 p 17 5 Plug the other end of the power ...

Page 10: ...maged contact our Technical Assistance Department at 1 630 378 3590 in the USA or 905 568 7140 in Canada PREPARING THE UNIT FOR INSTALLATION 1 Be sure to hold the handles on both sides of the unit to unpack the unit and carry it to the installation location Drum cartridge installed in unit Operation manual AL 1530CS AL 1540CS AL 1551CS Software CD ROM TD cartridge ...

Page 11: ...power cord and TD cartridge 3 Release the scan head locking switch The scan head locking switch is under the original table If the switch is locked the unit will not operate Unlock the switch as shown below AL 1551CS AL 1540CS AL 1551CS only AL 1215 AL 1530CS AL 1215 AL 1530CS AL 1540CS AL 1551CS AL 1540CS AL 1551CS Lock Unlock Grasp here and turn in the direction of the arrow ...

Page 12: ... fusing unit by pulling the strings upward one at a time 3 Push gently on both sides of the front cover to open the cover 4 Remove the TD cartridge from the bag Remove the protective paper Hold the cartridge on both sides and shake it horizontally four or five times Hold the tab of the protective cover and pull the tab to your side to remove the cover CAUTION tape Protective pins 4 or 5 times ...

Page 13: ...ase button 6 Close the front cover and then the side cover by pressing the round projections near the side cover open button When closing the covers be sure to close the front cover securely and then close the side cover If the covers are closed in the wrong order the covers may be damaged ...

Page 14: ...o maintain copying quality At this time the scan head moves automatically This is normal and does not indicate unit trouble If you use the unit in a country other than the country where the unit was purchased you will need to make sure that your local power supply is compatible with your model If you plug the unit into an incompatible power supply irreparable damage to the unit will result Only in...

Page 15: ...his state the settings in the following table are used Power off methods If not used for a certain period of time the unit will automatically enter auto power shut off mode p 54 in order to minimize power consumption In cases where the machine will not be used for a long time turn off the power switch and remove the power cord from the outlet Copy quantity 1 copy Exposure adjustment AUTO Zoom 100 ...

Page 16: ...x 11 is the maximum size that can be fed through the single bypass or the multi bypass tray Special papers such as transparency film labels and envelopes must be fed one sheet at a time through the single bypass or the multi bypass tray Type of paper feeding Type of media Size Weight Paper tray Standard paper Letter 8 1 2 x 11 Legal 8 1 2 x 14 Invoice 5 1 2 x 8 1 2 15 lbs to 21 lbs 56g m2 to 80g m...

Page 17: ...te of the paper tray 3 Store the pressure plate lock which has been removed in step 2 To store the pressure plate lock rotate the lock to fix it on the relevant location 4 Adjust the paper guides on the paper tray to the copy paper width and length Squeeze the lever of paper guide and slide the guide to match with the width of the paper Move paper guide to the appropriate slot as marked on the tra...

Page 18: ...in the stack is the same size and type When loading paper ensure there is no space between the paper and the guide and check if the guide is not set too narrow causing the paper to bend Loading paper in these ways will result in document skew or a paper jam When not using the unit for an extended period remove all paper from the paper tray and store it in a dry place If paper is left in the unit f...

Page 19: ...e multi bypass tray and extend the tray 2 Set the paper guides to the paper width Insert the paper print face down all the way into the multi bypass tray The multi bypass tray AL 1551CS can hold maximum of 50 sheets of paper Capacity will vary depending on the type of paper loaded The single bypass AL 1215 AL 1530CS AL 1540CS can hold one sheet of paper The original image must be smaller than the ...

Page 20: ... stack up If you insert a sheet of paper into the single bypass when multiple copies have been set with the copy quantity setting p 49 the copy quantity setting will change to 0 and only one copy will be made When copying onto transparency film remove each copy promptly Do not let copies stack up Note for loading envelopes Envelopes must be fed narrow side into the feed slot at a time Do not use n...

Page 21: ...unction of this unit with TWAIN compliant and WIA compliant application Printer driver Enables you to use the printer function of this unit with your computer Print Status Window The print state and information on current printing are displayed on the status monitor window Sharpdesk An integrated software environment that makes it easy to manage document and image files and launch applications But...

Page 22: ...t s scanner function cannot be used Computer type IBM PC AT or compatible computer equipped with a USB1 1 1 or bi directional parallel interface IEEE 1284 Operating system 2 Windows 95 Windows 98 Windows Me Windows NT Workstation 4 0 ServicePack 5 or later 3 Windows 2000 Professionall 3 Windows XP Professional 3 Windows XP Home Edition 3 Display 800 x 600dots SVGA display with 256 colors or better...

Page 23: ...000 USB interface p 25 Parallel Installing onto Windows 95 98 Me NT4 0 2000 Parallel interface p 28 Windows 2000 USB Installing onto Windows 98 Me 2000 USB interface p 25 Parallel Installing onto Windows 95 98 Me NT4 0 2000 Parallel interface p 28 Windows 95 NT 4 0 Parallel Installing onto Windows 95 98 Me NT4 0 2000 Parallel interface p 28 For this description it is assumed that the mouse is conf...

Page 24: ...selected in step 4 1 After confirming the message in the Welcome window click the Next button 2 A dialog box appears asking you to verify that the USB or parallel interface cable is not connected to the MFP Make sure that the interface cable is not connected and click the Next button If the language selection screen appears after you double click the setup icon select the language you wish to use ...

Page 25: ...d to Windows Startup check Yes and click the OK button The setup program will start to copy the files 5 Click the Finish button when the message informs you that setup is successful The Sharpdesk installer will start 8 Begin installation of the Sharpdesk This step will start if it was selected in step 4 1 After confirming the message in the Welcome to Sharpdesk installation window click the Next b...

Page 26: ...xt button 2 The Hardware Installation dialog box will appear Click the Continue Anyway button 3 When installation of the driver is completed click the Finish button to finish the scanner driver installation 12 Begin installation of the printer driver 1 SHARP AL xxxx where xxxx is the model name of your MFP will appear in the Found New Hardware Wizard dialog box Select Install the software automati...

Page 27: ...ware packages to be installed on the screen and then click the Start button The software packages to be installed will be displayed on the screen If inappropriate packages are displayed click the Back button to select appropriate packages again When any of Hardware Found or Found New Hardware Wizard messages appear during the software installation be sure to click the Cancel button If the language...

Page 28: ...are not using a parallel interface cable for connection to the MFP please click the No button 5 When the The MFP driver installation is complete dialog box appears click the OK button The Button Manager installer will start 7 Begin installation of the Button Manager This step will start if it was selected in step 4 1 After confirming the message in the Welcome window click the Next button 2 Read t...

Page 29: ... installation 5 Click the Finish button when the message to inform you of the completion of the installation appears 9 Click the Close button when the message to inform you of the completion of the installation appears When the Now connect the MFP interface cable to the PC dialog box or After Windows system restarts dialog box appears click the OK button 10 Make sure that the power of the MFP is t...

Page 30: ... connected and click OK 6 Check the contents of the package on the screen and then click the Start button The software packages to be installed will be displayed on the screen If inappropriate packages are displayed click the Back button to select only appropriate software packages When any of Hardware Found or Found New Hardware Wizard messages appear during the software installation be sure to c...

Page 31: ...hen the Model screen will appear Select the model number that is the same as the model name of your MFP and click the Next button Be sure to select the displayed model number that is the same as the MFP s model name If they are not the same the driver will not be installed correctly 5 Establish the printer settings and click the Next button Select LPT1 for the port to be used If LPT1 does not appe...

Page 32: ...ing for Windows you should hit Skip appears answer the question to continue the Sharpdesk installation 5 Click the Finish button when the message to inform you of the completion of the installation appears 9 Click the Close button when the message to inform you of the completion of the installation appears When the Now connect the MFP interface cable to the PC dialog box or After Windows system re...

Page 33: ...ccurred ONLINE indicator The ONLINE key is pressed and on line and off line are changed On Indicates the unit is ready for printing or scanning is being performed On line Blinking Printing or data is being received from a computer Off Copying is being performed Off line Power save indicator On Indicates the unit is in a power save mode Blinking Indicates that the unit is initializing when the side...

Page 34: ...here xxxx is the model name of your unit printer driver icon and from the File menu select Properties 4 Click Printing Preferences button in the General tab On Windows 95 98 Me click the Setup tab The printer driver setup screen will appear For problems with the printer function see the online manual or the help file for the driver On windows NT 4 0 select Document Defaults to open the printer dri...

Page 35: ...rt printing For details on print settings see the online manual or the help file for the printer driver If copying is being performed when printing is started copying will continue After copying is complete printing will be executed when the clear key is pressed twice the ONLINE key is pressed to switch the unit to the online state or approximately 60 seconds auto clear time elapse The auto clear ...

Page 36: ... menu that appears 2 In the Properties screen click the Events tab 3 Click the Select an event button and select ScanMenu SC1 from the pull down menu Select Button Manager SHARP Personal MFP series in Start this program and click Apply 4 Repeat Step3 to set ScanMenu SC2 through ScanMenu SC6 Click the Select an event button and select ScanMenu SC2 from the pull down menu Select Button Manager SHARP...

Page 37: ...rough ScanMenu SC6 Click the Scanner events and select ScanMenu SC2 from the pull down menu Select Button Manager SHARP Personal MFP series in Start this program and click Apply Do the same for each ScanMenu through ScanMenu SC6 When the settings have been completed click the OK button to close the screen When the settings have been completed in Windows start the Button Manager Adjust detailed set...

Page 38: ...For details on configuring the scan settings in Button Manager see the online manual or the help file This is the corresponding setting in the Button Manager to automatically send image s in full color at 75 dpi to Sharpdesk using the operation panel SC1 SCANNER key selection This dialog shows the SC1 event set to go directly to Button Manager With the Button Manager set to send the image to Sharp...

Page 39: ... scanned images to any application that can be selected in Button Manager This can be done with the Windows OS showing the Event Manager selection dialog or directly into a selected application if the Button Manager is the only allowed handler for device events from the SHARP AL xxxx where xxxx is the model name of your unit This is done by changing the Windows device settings for the AL xxxx wher...

Page 40: ...camera device register with the Windows Event Manager and shown as available in the registered applications The path an event takes to get to the user s selected application depends upon the event settings for the device Scanner AL xxxx where xxxx is the model name of your unit SCANNER key pressed Event Manager Windows OS Event Manager selection dialog Displayed on screen User selects an applicati...

Page 41: ...Destination Setting Dialog Box p 36 and then open the settings window of the Button Manager Scanning is not possible during a copy job If the SCANNER key is pressed during a print job the scan job will be stored When scanning an original that has been placed in the SPF only one original can be placed unless you are using Sharpdesk Application number Application launched SC1 Sharpdesk Full color if...

Page 42: ...Windows as explained in Setting up the Button Manager p 34 If step 4 is performed with the Show TWAIN setting screen when scanning checkbox selected in the Scan Button Destination Setting Dialog Box p 36 the TWAIN settings screen p 41 will automatically appear Check the settings and then press the start key again or click the Scan button in the TWAIN setting screen to start scanning The scanned da...

Page 43: ...or scanning refer to the online manual and help file and click the Scan button Scan is started If you use more than one scanning device select the scanner you want to use through the application The method for accessing the Select Scanner option depends upon the application For more information see the online manual or the help file of your application Click here ...

Page 44: ...aging Tasks 3 The Scanner and Camera Wizard appears Click Next and establish the basic settings for scanning For information on the settings see the Windows XP help file After completing each setting click Next 4 Select a name format and folder for the scanned image For information on the image name file format and folder see the Windows XP help file 5 Scanning begins When scanning ends select the...

Page 45: ... EnglishA folder and then double click the AL_1530CS_1540CS_1551CS pdf icon The following window will appear 5 Click the to read the online manual To close the online manual click the button located at the top right of the window Installing Acrobat Reader 1 Turn on your computer 2 Insert the CD ROM into the CD ROM drive 3 Click the start button click My Computer and then double click the CD ROM ic...

Page 46: ... icon in the printer dialog box and then click Properties 4 Click the Ports tab Details tab on Windows 95 98 Me in the Properties dialog box select FILE in the Print to the following port list box and click the OK 5 Right click the icon of the printer to be used and click Properties 6 Click the Ports tab Details tab on Windows 95 98 Me in the Properties window select LPT1 or the currently used por...

Page 47: ...terface cable 2 Ensure that your computer and unit are turned off 3 Insert the cable into the parallel interface connector located on the rear of the unit and fasten with clasps 4 Insert the other end of the cable into the interface connector of your computer If you intend to use the unit as a scanner it must be connected to your computer with a USB interface cable The scanner function cannot be u...

Page 48: ...paper 2 Place the original If you are using the original table see Using the original table p 47 If you are using the SPF RSPF see Using the SPF RSPF p 48 When copying onto paper larger than 8 1 2 x 11 size pull out the paper output tray extension 4 Start copying Press the start key 3 Select the copy settings If you wish to copy using the initial settings p 13 proceed to the next step To set the n...

Page 49: ...iginal cover SPF RSPF and place the original 2 Place an original face down on the original table Align it with the original scale and the centering mark Gently close the original cover SPF RSPF Do not insert paper in the single bypass when a copy job from the paper tray is in progress This will cause a misfeed If you start a print job while a copy job is in progress the print job will begin when t...

Page 50: ...ng mode is ON See USER PROGRAMS p 55 Before feeding originals in the original feeder tray be sure to remove any staples or paper clips from them Before placing curled or wavy originals into the original feeder tray be sure to flatten them If not original misfeeds may result The SPF RSPF indicator on the operation panel will light up If this indicator does not light up the originals are not properl...

Page 51: ...copy density manually or to copy photographs the exposure level can be adjusted in five steps manually 1 Press the exposure mode selector key to select the MANUAL mode or PHOTO mode 2 Use the light and dark keys to adjust the exposure level If exposure level 2 is selected the two left handmost indicators for that level will light up simultaneously Also if level 4 is selected the two right handmost...

Page 52: ...ress and hold down the exposure mode selector key for approximately 5 seconds The PHOTO indicator will go out and the AUTO indicator will begin to blink One or two light and dark indicators corresponding to the automatic exposure level which has been selected will light up 4 Press the light or dark key to lighten or darken the automatic exposure level as desired If exposure level 2 is selected the...

Page 53: ... a zoom ratio When a ZOOM or key is pressed the ZOOM indicator will light up and the zoom ratio will be displayed in the display To verify a zoom setting without changing the zoom ratio press and hold down the copy ratio display key When the key is released the display will return to the copy quantity display To reset the ratio to 100 press the copy ratio selector key repeatedly until the 100 indi...

Page 54: ...and Turn on Short Edge Making two sided copies 1 Place the original s on the original table or in the RSPF see ORIGINAL PLACEMENT p 47 2 Select two sided copy mode When making two sided copies from the original table the paper size must be letter When making two sided copies from the RSPF letter legal and invoice sizes can be used Non standard size paper cannot be used When making two sided copies...

Page 55: ...e 48 3 Select the copy settings See SET THE COPY QUANTITY p 49 EXPOSURE ADJUSTMENT PHOTO COPYING p 49 and REDUCTION ENLARGEMENT ZOOM p 51 Using the original table If you are using the original table copying is only possible in one sided to two sided mode A above 1 Press the start key The original is scanned into the unit s memory and the number of the copy quantity blinks in the display 2 Place th...

Page 56: ... mode the power save indicator will light up and other indicators except the ONLINE indicator will go out The auto power shut off mode saves more power than the preheat mode but requires a longer time before starting copying To copy from the auto power shut off mode press the start key Then make desired copier selections and press the start key using the normal copying procedure Auto clear page 55...

Page 57: ...wer save modes auto clear time stream feeding mode and resolution of AUTO MANUAL mode 1 Press and hold down the light and dark keys simultaneously for more than 5 seconds until all the alarm indicators blink and appears in the display 2 Use the left copy quantity key to select a user program number 1 auto clear time 2 preheat mode 3 auto power shut off timer 4 stream feeding mode 5 auto power shut...

Page 58: ...The total number of copies will appear in two steps each with three digits Example Total number of copies is 1 234 Program No Mode Parameters 1 Auto clear time 0 OFF 1 10sec 2 30sec 3 60sec 4 90sec 5 120sec 2 Preheat mode 0 30sec 1 60sec 2 90sec 3 Auto power shut off timer 0 2min 1 5min 2 15min 3 30min 4 60 min 5 120min 4 Stream feeding mode 0 OFF 1 ON 5 Auto power shut off mode 0 OFF 1 ON 6 Resol...

Page 59: ...GE p 10 2 Gently pull the TD cartridge out while pressing the lock release button 3 Install a new TD cartridge To install the new cartridge see INSTALLING THE TD CARTRIDGE p 10 Be sure to use only genuine SHARP parts and supplies After the unit stops it may be possible to make a few more copies by taking the TD cartridge out of the unit shaking it horizontally then reinstalling it If copying is no...

Page 60: ...placed Replace the drum cartridge at this time 1 Remove the TD cartridge see TD CARTRIDGE REPLACEMENT p 57 2 Hold the drum cartridge handle and gently pull the cartridge out Dispose of the old drum cartridge in accordance with local regulations 3 Remove the new drum cartridge from the protective bag and remove the protective cover from the cartridge Then gently install the new drum cartridge When ...

Page 61: ...PF RSPF Stains on the glass SPF RSPF scanning window AL 1540CS AL 1551CS cover or SPF RSPF roller will also be copied Wipe the glass SPF RSPF scanning window cover and SPF RSPF roller with a soft clean cloth If necessary dampen the cloth with a glass cleaner When closing the covers be sure to close the front cover securely and then close the side cover If the covers are closed in the wrong order t...

Page 62: ... out by holding the tab Set the charger cleaner onto the right end of the transfer charger gently slide the cleaner to the left end and then remove it Repeat this operation two or three times 4 Return the charger cleaner to its original position Close the side cover by pressing the round projections near the side cover open button 5 Turn the power switch on p 12 Slide the charger cleaner from the ...

Page 63: ...matic exposure mode Adjust the automatic exposure level 50 Is the unit in the photo exposure mode Cancel the photo exposure mode 49 Dust dirt smudges appear on copies Original table or original cover dirty Clean regularly 59 Original smudged or blotchy Use a clean original Striped copies Is transfer charger clean Clean the transfer charger 60 Paper misfeeds frequently Non standard paper used Use s...

Page 64: ...iption of E Misfeed in the SPF RSPF 66 Power save indicator is steadily lit The unit is in the preheat mode Press any key to cancel the preheat mode 54 The unit is in the auto power shut off mode Press the start key to cancel the auto power shut off mode 54 The paper tray indicator is blinking The paper tray is not installed properly Push the tray into the unit securely CH is blinking in the displ...

Page 65: ...66 1 Open the multi bypass tray AL 1551CS and side cover in that order To open the multi bypass tray see The multi bypass tray AL 1551CS p 17 To open the side cover see INSTALLING THE TD CARTRIDGE p 10 2 Check the misfeed location Remove the misfed paper following the instructions for each location in the illustration below If the misfeed indicator blinks proceed to A Misfeed in the paper feed are...

Page 66: ...d indicator will go out and the start indicator will light up B Misfeed in the fusing area 1 Lower the fusing unit release lever The fusing unit is hot Do not touch the fusing unit when removing misfed paper Doing so may cause a burn or other injury Do not touch the surface of the drum green portion of the drum cartridge when removing the misfed paper Doing so may damage the drum and cause smudges...

Page 67: ...sfeed in the fusing area p 64 2 Open the front cover To open the front cover see INSTALLING THE TD CARTRIDGE p 10 3 Rotate the feeding roller in the direction of the arrow and gently remove the misfed paper from the exit area The fusing unit is hot Do not touch the fusing unit when removing misfed paper Doing so may cause a burn or other injury Do not touch the surface of the drum green portion of...

Page 68: ...sfeed indicator will go out and the start indicator will light up E Misfeed in the SPF RSPF An original misfeed may occur at one of three locations if the misfed original is seen from the original feeder tray A in the original feeder tray if the misfed original is not seen from the original feeder tray B in the exit area or C under the feeding roller Remove the misfed original following the instru...

Page 69: ...rection of the arrow while rotating the knob With the RSPF after removing the misfed original from the exit area be sure to insert the reversing tray into the exit area until it locks in place A number may appear in the display after a minus sign indicating the number of the originals that must be returned to the original feeder tray Open and close the SPF RSPF to clear the SPF RSPF misfeed indica...

Page 70: ... Printing size 3 1 2 x 5 1 2 to 8 1 2 x 14 1 Image loss Max 5 32 4mm 2 Max 11 64 4 5mm 3 Max 15 64 6mm 4 Copy speed 12 pages min 15 pages min Print speed Max 12 pages min Letter or A4 Continuous copying printing Max 99 pages subtractive counter First copy print time Approximately 9 6 seconds 5 paper A4 exposure mode AUTO copy ratio 100 Copy ratio Variable 25 to 400 in 1 increments total 376 steps ...

Page 71: ...492 5mm Height 11 6 295 6mm 11 6 495 6mm 15 0 380 4mm 18 3 465 4mm Operating conditions Temperature 50 F to 86 F 10 C to 30 C Humidity 20 to 85 Emulation SHARP GDI Interface USB interface USB1 1 Standard IEEE1284 compliant bi directional parallel interface Only for printer Noise level Sound Power Level LwA 1B 10dB Copying 6 0 B Standby 3 7 B Sound Pressure Level LpA bystander positions Copying 46 ...

Page 72: ...face cable IEEE 1284 Shielded type bi directional parallel interface cable 6 feet Max USB interface cable Shielded twisted pair cable high speed transmission equivalent 6 feet Max Be sure to use only genuine SHARP parts and supplies For best copying results be sure to use only SHARP Genuine Supplies which are designed engineered and tested to maximize the life and performance of SHARP copiers Look...

Page 73: ...in the front of the paper tray 5 Push the paper tray back into the unit 6 Lock the scan head locking switch p 9 7 Close the multi bypass tray and the paper output tray extension and attach the packing materials and tape which were removed during installation of the unit See PREPARING THE UNIT FOR INSTALLATION p 8 8 Pack the unit into the carton See CHECKING PACKED COMPONENTS AND ACCESSORIES p 8 Pr...

Page 74: ... manual 4 Copy flow 46 Copy quantity 49 Copy quantity key 6 49 55 Copy ratio display key 6 51 Copy ratio selector indicator 6 51 Copy ratio selector key 6 51 D Dark key 6 49 Display 6 Displaying total number of copies 56 Disposing of TD cartridge 57 Drum cartridge 5 58 Drum cartridge replacement 58 Drum replacement required indicator 6 58 62 E Exposure adjustment 49 Exposure mode indicator 6 49 Ex...

Page 75: ...er on 12 Power save indicator 6 31 Power switch 5 12 Preheat mode 55 Preparing the unit for installation 8 Printer driver 19 Proper storage 71 R Reduction enlargement zoom 51 S Scan head locking switch 9 Scanner driver 19 SCANNER indicator 6 31 SCANNER key 6 39 Scanning from your computer 40 Scanning with the Scanner and Camera Wizard 42 Setting up the unit 7 Setup procedure 7 Sharpdesk 19 Side co...

Page 76: ...e TD cartridge 10 Loading paper Multi bypass tray 17 Paper tray 15 Single bypass 18 Loading the original Original table 47 SPF RSPF 48 Moving the unit 71 Opening the printer driver 32 Power off 13 Power on 12 Preparing for installation 8 Printing 33 Removing paper jams Fusing area 64 Lower paper feed area 66 Paper feed area 64 SPF RSPF 66 Transport area 65 Replacing the drum cartridge 58 Replacing...

Page 77: ...another or over a network 3 Termination This license is effective until terminated You may terminate this License at any time by destroying the Software and related documentation and all copies thereof This License will terminate immediately without notice from SHARP and or SHARP S Licensors if you fail to comply with any provision of this License Upon termination you must destroy the Software and...

Page 78: ...L OR WRITTEN INFORMATION OR ADVICE GIVEN BY SHARP OR A SHARP AUTHORIZED REPRESENTATIVE SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY SHOULD THE SOFTWARE PROVE DEFECTIVE YOU AND NOT SHARP OR A SHARP AUTHORIZED REPRESENTATIVE ASSUME THE ENTIRE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE AB...

Page 79: ... 2613 United Kingdom Sharp Electronics U K Ltd Telephone number for information 08705 274 277 France Sharp Electronics France S A Telephone number for information 01 49 90 34 00 Austria Sharp Electronics GMBH Telephone number for information 01 727 19 0 Italy Sharp Electronics Italia S P A Telephone number for information 02895951 Spain Sharp Electronics Espana S A Telephone number for information...

Page 80: ...tely with water for 15 minutes If irritation does occur consult medical personnel Ingestion Rinse with water and drink several glasses of water If irritation or discomfort does occur consult medical personnel 5 FIRE FIGHTING MEASURES Extinguishing Media water CO2 foam and dry chemicals Special Fire fighting Procedures None Fire and Explosion Hazards Toner material like most finely divided organic ...

Page 81: ...TY AND REACTIVITY Stability Stable Hazardous Reactions Dust explosion like most finely divided organic powders Conditions to avoid Electric discharge throwing into fire Materials to avoid Oxidizing Materials Hazardous Decomposition Products CO CO2 and NOX Further Information None 11 TOXICOLOGICAL INFORMATION Acute Toxicity Ingestion oral LD50 2000mg kg Rats Dermal LD50 2000mg kg Rats Inhalation No...

Page 82: ...le rules or order under TSCA SARA Superfund Amendments and Reauthorization Act Title III 302 Extreme Hazardous Substance None 311 312 Hazard Classification None EU Information 1999 45 EC and 67 548 EEC Symbol Indication Not required R Phrase Not required 76 769 EEC All chemical substances in this product comply with all applicable rules or order under 76 769 EEC 16 OTHER INFORMATION NFPA Rating US...

Page 83: ...ectronics Europe GMBH Sonninstrasse 3 20097 Hamburg Telephone number for information 040 2376 2613 United Kingdom Sharp Electronics U K Ltd Telephone number for information 08705 274 277 France Sharp Electronics France S A Telephone number for information 01 49 90 34 00 Austria Sharp Electronics GMBH Telephone number for information 01 727 19 0 Italy Sharp Electronics Italia S P A Telephone number...

Page 84: ...ur consult medical personnel 5 FIRE FIGHTING MEASURES Extinguishing Media water CO2 foam and dry chemicals Special Fire fighting Procedures None Fire and Explosion Hazards Like most finely divided organic powders it may form an explosive mixture 6 ACCIDENTAL RELEASE MEASURES Personal Precautions None Environmental Precautions None Methods for Cleaning Up Wipe off with paper or cloth Do not use vac...

Page 85: ...ponents Dermal LD50 2000mg kg Rats Inhalation No data Eye irritation Not an irritant Rabbits Skin irritation Not an irritant Rabbits Skin sensitizer No sensitization Mutagenicity Negative Ames Test Carcinogenicity In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen possible human carcinogen This classification is given to chemicals for which there is inadequate human evidence but su...

Page 86: ...EEC Symbol Indication Not required R Phrase Not required 76 769 EEC All chemical substances in this product comply with all applicable rules or order under 76 769 EEC 16 OTHER INFORMATION NFPA Rating USA Health 1 Flammability 1 Reactivity 0 WHMIS Legislation Canada This product is not a controlled product References IARC 1996 IARC monographs on the Evaluation of the Carcinogenic Risk of Chemicals ...

Page 87: ...the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shielded cables must be used...

Page 88: ...8QSZ3 2002H Printed on Recycled Paper SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07430 2135 www sharp usa com SHARP ELECTRONICS OF CANADA LTD 335 Britannia Road East Mississauga Ontario L4Z 1W9 SHARP CORPORATION 1 ...