19
LC-20E1U
LC-20E1UB/UW
Adjustment process mode menus at a glance
Page
Item
Initial setting Function
Adjust/modify
1
MODEL
E1U
Model number
INCH SIZE
20
Inch unit select
Adjustment
SYSTEM
N358
Color system select
NTSC PWN FREQ
OCO
Dimmer frequency setting
PAL PWM FREQ
OBD
Dimmer frequency setting
NTSC PWM DUTY
0
Dimmer duty setting
PAL PWM DUTY
0
Dimmer duty setting
TV GAIN
OFF
Auto gain setting in TV mode
ERROR NO RESET
0
Lamp error count & reset
No. of lamp error detections
PUBLIC MODE
OFF
HOTEL MODE
V-CHIP (US)
1
VCHIP line mute setting
CANADIAN VCHIP
OFF
Canadian VCHIP setting
E1UVER
Microprocessor Ver. No. display
Basic settings
2
COM BIAS
90
Counter bias adjustment
Adjustment
NTSC TAMP
20
TAMP adjustment
Adjustment
PAL-M TAMP
20
TAMP adjustment
Adjustment (Same setting as for NTSC TAMP)
PAL-N TAMP
20
TAMP adjustment
Adjustment (Same setting as for NTSC TAMP)
RCUTOFF
-1
White balance adjustment (Red)
Adjustment
GCUTOFF
0
Green cutoff adjustment
BCUTOFF
-1
White balance adjustment (Blue)
Adjustment
G3
00
Data read value
B3
00
Data read value
R3
00
Data read value
G1
00
Data read value
B4
00
Data read value
Y
00
Data read value at TAMP adjustment
TAMP H
CA
Y upper limit setting at TAMP adjustment
TAMP L
BB
Y lower limit setting at TAMP adjustment
GAIBU VER
External version display
3
TV NTSC CONT
51
Video contrast setting (TV NTSC)
TV PAL-M CONT
51
Video contrast setting (TV PAL-M)
TV PAL-N CONT
51
Video contrast setting (TV PAL-N)
AV N358 CONTRAST
49
Video contrast setting (Composite, S Video)
AV PAL CONTRAST
49
Video contrast setting (Composite, S Video)
AV SECAM CONTRAST
49
Video contrast setting (Composite, S Video)
AV PAL-M CONTRAST
49
Video contrast setting (Composite, S Video)
AV PAL-N CONTRAST
49
Video contrast setting (Composite, S Video)
AV PAL60 CONTRAST
49
Video contrast setting (Composite, S Video)
G3
00
Data read value
B3
00
Data read value
R3
00
Data read value
G1
00
Data read value
B4
00
Data read value
Y
00
Data read value
Video adjustments
4
VOLUME
20
Volume
AVC
OFF
AVC setting
CARRIER MUTE
ON
Audio output setting out of sync with TV
IGR THR
12D
IGR THRESH LEVEL
MSP DATA
0
Audio IC MSP data write & read
MSP DATA
WAIT
Write & read execution
PRESCALE FM/AM-M
17
Pre-scale setting (TV)
PRESCALE SCART
15
Pre-scale setting (external input)
FSP TEST
OFF
Audio test (FS mute ON/OFF)
5
MDB
ON
MDB
LVL
-10
WF level adjustment
FRQ
120
WF LPF cutoff frequency setting
STR
40
MDB amount of effects setting
LMC
-27
MDB limit value setting
HMC
00
MDB harmonics effect setting
Audio adjustments
Summary of Contents for Aquos LC 20E1U
Page 32: ...35 34 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H OVERALL WIRING DIAGRAM ...
Page 35: ...39 38 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë DIGITAL Unit 1 5 ...
Page 36: ...41 40 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë DIGITAL Unit 2 5 ...
Page 37: ...43 42 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë DIGITAL Unit 3 5 ...
Page 38: ...45 44 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë DIGITAL Unit 4 5 ...
Page 39: ...47 46 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë DIGITAL Unit 5 5 ...
Page 40: ...49 48 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë ANALOG Unit 1 2 ...
Page 41: ...51 50 LC 20E1U LC 20E1UB UW 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H Ë ANALOG Unit 2 2 ...
Page 42: ...52 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW Ë INVERTER A Unit ...
Page 43: ...53 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW Ë INVERTER B Unit ...
Page 46: ...56 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW DIGITAL Unit Side B ...
Page 49: ...59 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW ANALOG Unit Side A ...
Page 51: ...62 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW INVERTER A Unit Side A ...
Page 53: ...64 6 5 4 3 2 1 A B C D E F G H LC 20E1U LC 20E1UB UW INVERTER B Unit Side A ...