LC-52/60/70LE640U/C6400U,LC-80LE633U/844U (1st Edition)
5 – 23
*1 Details of P1.12 (NORMAL STANDBY CAUSE)
When TV set is powered off due to normal use or product specification, the last cause will be recorded.
The code, character string and description for the standby cause are below.
If you power off by remote, the cause will not be recorded.
*2 Details of P1.13 (ERROR STANDBY CAUSE)
When TV set is powered off due to any anomaly detection, the past 5 causes will be recorded.
You can confirm the time those causes occurred and character string in the adjustment process mode menu. (Page 27/28)
The time is accumulated total after TV set is powered on, and the value corresponds to “Center Acutime” in the adjustment process mode menu.
The code, character string and description for the standby cause are below.
If no error has occurred, the code is 0 and the character string is “NO RECORD”.
Code
Character string
Description
2
NO_OPERT
No operation off
3
NO_SIGNA
No signal off
6
SLEEP_TM
Off timer
8
OFF_232C
Command from RS232C
Code
Character string
Description
1A
E_MONITR
Monitor trouble detected
1C
E_CVICBT
Driver boot error
22
E_TCNERR
Software abnormality of LCD controller
48
E_MRESET
Failure of resetting menu settings (Initial Setup - Reset)
50
E_TCNF_S
T-CON FPGA status error
54
E_TCON_E
T-CON hung-up
Monitor ERR STBY table
Outline: Communication/Power failure detected by the monitor microprocessor is stored in EEPROM, and last 4 abnormal
can be confirmed in the Process mode A.
Location: Page 1 of the process mode A: MONITOR ERR CAUSE. “0” if there is no error. It is cleared to 0 on the last page of
the process mode A.
Display
Error description
02
Initial communication from the main CPU is not received.
Check UART bus between main CPU and sub CPU.
03
Only the initial communication is received.
04
Until panel information request reception
05
Until initialization completion reception
06
Until version notification transmission
07
Until start-up information notification transmission
08
Until start-up information response reception
09
Until time-out setting reception
0A
Request time-out
0B
Restart time-out during the beginning of time acquisition start-up
0C
Ending sequence time-out
0D
Preset start-up time-out during completion
0E
Download, start-up time-out
0F
Time acquisition time-out
11
Regular communication time-out
16
Backlight error
See p.6-5
1A
Monitor temperature failure
- Check TV setting environment
- Check the other monitor (ref No.)
1E
DET_13V failure
Check 13V power line.
1F
DET_D3V3 failure
Check D3V3 power line.
21
DET_PNLxxV failure
Check T-CON power line
23
Error standby request from the main CPU
Check ERROR STANDBY CAUSE (p.5-8)
Summary of Contents for AQUOS LC-52LE640U
Page 8: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 1 2 2 SPECIFICATIONS LC 80LE633U 844U ...
Page 9: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 1 3 ...
Page 14: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 2 5 LC 80LE844U ...
Page 15: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 2 6 ...
Page 16: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 2 7 ...
Page 19: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 3 3 3 DIMENSIONS LC 80LE633U 844U ...
Page 168: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition 8 6 MEMO ...
Page 190: ...LC 52 60 70LE640U C6400U LC 80LE633U 844U 1st Edition ...