LC-60E77UN/LC-65E77UM/LC-C6077UN/LC-C6577UM
5 – 14
9. White balance adjustment
9.1. White balance adjustment (for LC-60E77UN/LC-C6077UN)
Adjustment point
Adjustment conditions
Adjustment procedure
1
Setting
(For details about the adjustment procedure, refer to “Kameyama Model Integrated Mon-
itor WB Adjustment Specification V1.4”.)
1) Set the set to the following conditions.
AV MODE: [DYNAMIC]
Backlight: +16
Active Contrast: OFF
Aging Time: Min. 60 minutes
2) Connect the set with the white balance adjustment jig.
2
Automatic adjust-
ment execution
[Command]
Process mode
KRSW0001
KKT10037
Setting
KYOF0000
OSDS0001
SBSL0016
Multi-point adjustment
mode
MSET0001
Point 6
WBI60928
MG6G****
MG6B****
MG6R****
Point 5
WBI50808
MG5G****
MG5B****
MG5R****
[Adjustment procedure]
1) Transmit the “Monitor adjustment process” code using the remote control.
2) Set the point 6 to the specified gradation, specify the strongest color as the fixed
color, and adjust the RGB so that it becomes the standard value through negative
adjustment.
3) Set the point 5 to the specified gradation, set the G correction value (3232 x G value
of point 6/3712) (fractions rounded off), and adjust the RB so that it becomes the
standard value.
4) Set the point 4 to the specified gradation, set the G correction value (2784 x G value
of point 6/3712) (fractions rounded off), and adjust the RB so that it becomes the
standard value.
5) Set the point 3 to the specified gradation, set the G correction value (1920 x G value
of point 6/3712) (fractions rounded off), and adjust the RB so that it becomes the
standard value.
6) Set the point 2 to the specified gradation, set the G correction value (944 x G value of
point 6/3712) (fractions rounded off), and adjust the RB pattern so that it becomes the
standard value.
7) Set the point 1 to the specified gradation, set the G correction value (736 x G value of
point 6/3712) (fractions rounded off), and adjust the RB so that it becomes the stan-
dard value.
8) Write the adjustment value by the MSET0003 command and turn off the AC power.
* RGB initial value of point 6: Set gradation 3712
* RGB initial value of points 1 to 5: G correction value of each point
[Adjustment value]
* According to the “Standard settings” submitted by the Technical Department
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
Point 4
Level
Reference value
Adjustment spec
Inspection spec
WBI40696
Point 6
928
X=0.272
±
0.0010
±
0.0020
MG4G****
y=0.277
MG4B****
Point 5
808
X=0.272
±
0.0010
±
0.0020
MG4R****
y=0.277
Point 4
696
X=0.272
±
0.0015
±
0.0030
Point 3
y=0.277
WBI30480
Point 3
480
X=0.272
±
0.0020
±
0.0040
MG3G****
y=0.277
MG3B****
Point 2
236
X=0.272
±
0.0030
±
0.0060
MG3R****
y=0.277
Point 1
184
X=0.272
±
0.0045
±
0.0090
y=0.277
Point 2
WBI20236
MG2G****
MG2B****
MG2R****
Remarks
Setting conditions when performing inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Controst: OFF
Aging Time: Min. 60 minutes
Point 1
WBI10184
MG1G****
MG1B****
MG1R****
Writing
MSET0003