[Descriptive Conventions]
For the sake of keeping the use of information common among several models, this manual uses the following conventions:
AR-5XX:
Refers to model AR-501/505,
AR-4XX:
Refers to model AR-405,
AR-2X1/3X1/4XX/250/XX6: AR-281/286/405/250/336,
AR-2XX, 3XX:
Refers to model AR-280/285/335 for this issue.
*
The "X" stands for any numeral 0 to 9.
B. List
Code
Function (Purpose)
Main
Sub
1
1
Used to check the operation of the scanner unit and its
control circuit.
2
Used to check the operation of sensors and detectors in the
scanner section and the related circuit.
2
1
Used to check the operation of the automatic document
feeder unit and its control circuit.
2
Used to check the operation of sensors and detectors in the
automatic document feeder units and the related circuit.
3
Used to check the operation of the loads in the automatic
document feeder units and the control circuits.
3
2
Used to check the operation of sensors and detectors in the
and the related circuit.
3
Used to check the operation of the loads in the finisher and
the control circuit.
6
Used to adjust the finisher stacking capability. (Used to adjust
the stop position of the finisher paper width direction
alignment plate (jogger). This adjustment is made by
changing the width direction alignment plate home position by
the software.)
4
2
Used to check the operation of sensors and detectors in the
paper feed section (desk feed, large capacity tray) and the
related circuit.
3
Used to check the operation of the loads in the paper feed
section (desk paper feed, large capacity tray) and the control
circuits.
5
1
Used to check the operation of the display, LCD in the
operation panel, and control circuit.
2
Used to check the operation of the heater lamp and the
control circuit.
3
Used to check the oepration of the copy lamp and the control
circuit.
4
Used to check the operation of the discharge lamp and the
control circuit.
6
Used to check the operation of the separation lamp and its
control circuit. (AR-501/505/507 only)
6
1
Used to check the operation of the loads (clutches and
solenoids) in the paper transport system and the control
circuit.
2
Used to check the operation of each fan motor and its control
circuit.
7
1
Used to set the aging operation conditions.
6
Used to set the cycle of intermittent aging.
8
Used to set YES/NO of display of the warmup time.
8
1
Used to check the operation of the developing bias voltage in
each print mode and its control circuit. (For OPC drum type B)
2
Used to check and adjust the operation of the main charger
grid voltage in each print mode and the control circuit. (for
OPC drum type B)
6
Used to check and adjust the transfer charger current and the
control circuit.
7
Used to check and adjust the operation of the separation
charger voltage and its control circuit.
9
1
Used to check the operation of the loads (clutches and
solenoids) in the duplex section and the control circuit.
2
Used to check the operation of sensors and detectors in the
duplex section and the control circuit.
4
Used to check the operation of the duplex unit alignment plate
and its control circuit.
Code
Function (Purpose)
Main
Sub
10
0
Used to check the operation of the toner motor and its control
circuit.
(Note)
Do not execute this simulation with toner in the toner hopper.
If executed, excessive toner may enter the developing
section, causing an overtoner trouble. Be sure to remove the
toner motor from the toner hopper before executing this
simulation.
14
0
Used to cancel the self diag U1/LOC/U2/PF troubles.
15
0
Used to cancel the self diag U4 - 09/20/21/22 (large capacity
tray) trouble.
16
0
Used to cancel the self diag U2 trouble.
17
0
Used to cancel copy inhibition by the host computer during
the self diag PF.
21
1
Used to set the maintenance cycle.
22
1
Used to check the print out count of each section in each
operation mode.
(Used to check the maintenance timing.)
2
Used to check the total numbers of misfeed and troubles.
(When the number of misfeed is considerably great, it is
judged as necessary for repair. The misfeed rate is obtained
by dividing this count value with the total counter value.)
3
Used to check the misfeed positions and the number of
misfeed in each position. (If the number of misfeed is
considerably great, it can be judged as necessary for repair.)
(Sections other than ADF/RADF/SPF sections)
4
Used to check the total trouble (self diag) history.
5
Used to check the ROM version of each unit (section).
6
Used to output the list of the setting and adjustment data
(simulations, FAX soft switch, counters).
7
Used to display the key operator code. (This simulation is
used when the customer forgets the key operator code.)
8
Used to check the number of use of the staple, the ADF,
RADF, SPF, and scanning.
9
Used to check the number of use of each paper feed section.
(the number of prints)
10
Used to check the system configuration (option, internal
hardware).
11
Used to check the use frequency of FAX (send/receive).
(FAX model only)
12
Used to check the misfeed positions and the number of
misfeed at each position. (When the number of misfeed is
considerably great, is can be judged as necessary for repair.)
19
Used to display the scanner mode counter.
24
1
Used to clear the misfeed counter, the misfeed history, the
trouble counter, and the trouble history. (The counters are
cleared after completion of maintenance.)
2
Used to clear the number of use (the number of prints) of
each paper feed section.
3
Used to clear the data of the number of use of the staple, the
SPF, ADF, RSPF, RADF and scanning.
4
Used to reset the maintenance counter.
5
Used to reset the developer quantity counter. (The developer
counter of the installed developing unit is reset.)
6
Used to reset the copy counter.
7
Used to clear the OPC drum (membrane decrease)
correction counter.
(This simulation is executed when the OPC drum is replaced.)
9
Used to clear the printer print counter. (The counter is cleared
after completion of maintenance.)
7/13/2000
7 – 3
Summary of Contents for AR-250
Page 194: ......