AR-5012 SIMULATION, TROUBLE CODES 10 - 4
08
01
Developing bias
(Operation/Procedure)
When the START key is pressed, the developing bias is outputted for 30 sec.
02
Main charger (Grid high)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage HIGH mode.
03
Grid voltage (Low)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage LOW mode.
06
Transfer charger
(Operation/Procedure)
When the START key is pressed, the transfer charger output is supplied for 30 sec.
10
None Toner motor aging
(Operation/Procedure)
When the START key is pressed, the toner motor output is supplied for 30 sec.
14
None Cancel of troubles other than U2
(Operation/Procedure)
After canceling the trouble, the simulation is also automatically canceled.
16
None Cancel of U2 trouble
(Operation/Procedure)
1. When the START key is pressed, the EEPROM total counter check sum is rewritten and the trouble is canceled.
2. After canceling the trouble, the simulation is also automatically canceled.
20
01
Maintenance counter clear
When the PRINT switch is pressed, the maintenance count is cleared and the value “000000” is displayed.
21
01
Maintenance cycle setup
The currently set code (default) of the maintenance cycle is displayed, and the newly set data are saved.
02
Mini maintenance cycle setup (Valid only when the destination is set to Japan AB series.)
The currently set code (default) of the mini maintenance cycle is displayed, and the newly set data are saved.
22
01
Maintenance counter display
The display method is the same as the total count value display.
02
Maintenance preset value display
The quantity corresponding to the code set with 21-01 and 21-02 is displayed.
The display method is the same as the total count value display.
04
JAM total counter display
The display method is the same as the total count value display.
05
Total counter display
The total count value is displayed in 3 digits X 2 times repeatedly.
<Display example: 12345>
06
Developer counter display
The display method is the same as the total count value display.
12
Drum counter display
The display method is the same as the total count value display.
14
P-ROM version display
The main code and the sub code of the P-ROM version is displayed on the value display section in 2 digits alternately.
The display method is the same as the total count value display.
17
Copy counter display
The display method is the same as the total count value display.
Main
code
Sub
code
Content
Code
Setup
0
3,000 sheets
1
6,000 sheets
2
9,000 sheets
3
13,000 sheets
4
25,000 sheets
*Default
5
Free (999,999 sheets)
Code
Setup
0
5,000 sheets
*Default
1
10,000 sheets
2
Free (999,999 sheets)
012
→
Blank
→
345
→
Blank
→
012
0.7s
0.3s 0.7s
1.0s
0.7s