AR-5012 USER PROGRAMS 12 - 1
[12] USER PROGRAMS
The conditions of factory setting can be changed according to the use conditions.
1. Functions that can be set with user programs
* Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
2. Change the setting
Example: Changing the time to operate the auto clear function
(Change from 60 sec to 90 sec)
1) Press the right and the left exposure adjustment keys simulta-
neously to start setting.
• Keep pressing the keys for 5 sec.
• Display lamps (
,
,
,
) blink simultaneously and " -- " is
displayed on the copy quantity display.
2) Select the function code with the 10-digit key (copy quantity set
key).
• The number of the selected function blinks on the digit of 10 on the
copy quantity display.
• For auto clear, select " 1. "
• For setting, refer to the following function codes.
[Cancel]
If a wrong code is entered, press the clear key and enter the
correct function code.
* SPF only
3) Press the COPY button.
• The number blinking on the digit of 10 of the copy quantity display is
lighted.
• The number of the current set code blinks on the digit of 1.
4) Select the setting code with 1-digit key (copy quantity set key).
• To set to 90 sec, select " 4. "
• For setting, refer to the following set codes.
* Factory setting
• The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
[Cancel]
When a wrong number of the function code is set, press the
clear key and perform the procedure again from step 2.
5) Press the COPY button.
• The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
Note: To set another function, press the clear key after completion of
this operation and perform the procedure from step 2.
6) Press either one of the exposure adjustment keys (
or
) to
complete the setting.
• Display lamps (
,
,
,
) go off and the copy quantity dis-
play returns to the normal state.
Function
Contents
Factory setting
Auto clear
• When a certain time is passed after completion of copying, this function returns to the initial state
automatically. The time to reach the initial state can be set in the range of 30 sec to 120 sec by the unit
of 30 sec. This function can be disabled.
60 sec
Pre-heat
• When the copier is left unused with the power ON, the power consumption is automatically reduced to
about 40Wh/H (* Note).The time to start this function can be set in the range of 30 sec to 90 sec by the
unit of 30 sec. This function cannot be disabled.
• When this function is operated, the pre-heat lamp on the operation panel lights up. To return to the
initial state, press any key on the operation panel. (When the COPY button is pressed, a copy is made
after returning to the initial state.)
30 sec
Auto shut off passing
time
• When the copier is left unused with the power ON, the power consumption is automatically reduced to
about 18Wh/H (* Note). The time to start this function can be set in the range of 2 min to 120 min.
• When this function is operated, all the lamps except for the pre-heat lamp on the operation panel turn
off. To return to the initial state, press the COPY button.
5 min
Stream feeding
Only models with SPF
Set
Auto shut off setting
• Used to set or cancel this function.
Set
Auto/Manual mode
resolution setup
• Used to set the resolution in the auto/manual mode. The speed priority (300dpi) and the resolution
priority (600dpi) are effective for fine text and ultra fine text.
300 dpi
Function name
Function code
Auto clear
1
Pre-heat
2
Auto shut off passing time
3
Stream feeding
4*
Auto shut off setting
5
Auto/Manual mode resolution setup
6
Function name
Set code
Auto clear
0 (OFF)
1 (10 sec)
2 (30 sec)
*3 (60 sec)
4 (90 sec)
5 (120 sec)
Pre-heat
*0 (30 sec)
1 (60 sec)
2 (90 sec)
Auto shut off
0 (2 min)
*1 (5 min)
2 (15 min)
3 (30 min)
4 (60 min)
5 (120 min)
Stream feeding
0 (Cancel)
*1 (Setting)
Auto shut off setting
0 (Cancel)
*1 (Setting)
Auto/Manual mode resolution setup
*0 (300 dpi)
1 (600 dpi)