: Jan. 9 2004
1
AR-M550/M620/M700 INSTALLATION MANUAL (AR-CF2) 3 - 6
(9) Install the connection plate. (Use the packaged parts of
the finisher.)
Remark: The plate and the connection plate are common to the fin-
isher. Please reuse rail and connector plate for inserter.
(10) Connect the connector
1) Connect the finisher relay harness connector to the inserter con-
nector, and tighten the connector screw to fix it.
2) Fix the finisher relay harness to the rear side of the inserter with two
clamps.
3) Connect the inserter relay harness connector to the main unit con-
nector, and tighten the connector screw to fix the connector.
(11) Install the inserter to the main unit
1) Bring the inserter closer to the main unit.
2) Check that the main unit positioning pin enters smoothly into the
center of the inserter positioning guide.
1) Install the connection plate to the inserter with the fixing screws G
(2 pieces.).
1
1
2