background image

A-

UNIT

1/2"

1/4"

3/8"

1/4"

3/8"

1/4"

3/8"

1/4"

1/2"

1/4"

3/8"

1/4"

3/8"

1/4"

1/2"

1/4"

A-

UNIT

B-

UNIT

C-

UNIT

Connecting the pipes

Connect the pipes for the indoor unit first and then 

for the outdoor unit. 

(1) Tighten the 

flare

 nuts by 

hand

 for the 

first

 3-4 

turns.

(2) Use 

a

 wrench 

and

 torque wrench to tighten up 

the pipes.

• Do not over tighten the pipes; it may be de

-

formed or damaged. 

Notes:

 

Bend the pipes carefully as not to damage them.

 

Lay the drain hose below the pipes.

(

4) Flaring 

 

Flare processing 

dimensions(A)

(5) Checking

  T

o be flared perfectly circula

r.

 

Flare nut not missing.

A

B

D

C

Connecting the drain hose

The unit discharged water from its drain port. Con

-

nect a commercial drain hose if drainage is neces

-

sar

y. 

Flare nut

Connecting 7000/9000/12000 BTU/h-class indoor unit to 

the port “A-UNIT”

Make sure to use the joint, flare nut and seal ring.

Installation dimension

Referring to the figure, firmly fas

-

ten the outdoor unit with bolts.

The flare coupling refrigerant pipes.

Flaring the pipe end

(1) Cutting with a pipe cutter

 

Cut at a right angle.

(2) Deburring

 

Allow no cuttings in the pipe.

(3) Putting in the flare nut

ACCESSORIES

ITEMS

Q’ty APPLICATION

ITEMS

Q’ty APPLICATION

ITEMS

Q’ty APPLICATION

1  Manual

1

Installation manual

3  Drain tray

1

To connect the 

drain hose to the 

outdoor unit.

5  Joint

1

To connect 3/8" 

pipe to the port “A-

UNIT”

2  Cable fixing band

1

T

o bind the cables.

4  Drain joint

1

6  Seal Ring

1

7  Flare nut

    (3/8

"

)

1

1     OUTDOOR UNIT INSTALLATION

2     CONNECTING THE REFRIGERANT PIPES

MULTI SPLIT TYPE ROOM AIR CONDITIONER

INSTALLATION MANUAL

ENGLISH

INSTALLATION DIAGRAM

1000 

mm or more

400 

mm or more

  Install at least 2 indoor unit

s. 

 

Provide as much installation 

space as possible for efficient 

air-conditioning. 

For installation work

300 

mm or more

300 

mm or more

1. 

Place the outdoor unit on a stable base.

2. 

Provided sufficient space around the unit. It should also be well 

ventilated.

3. 

The unit should not be exposed to strong wind nor splashed 

with rain wate

r.

4. W

ater drain from the unit should be let out without problem. Lay 

a drain hose if required. In cold regions, installation of the drain 

pipe is not

 advisable as freezing could result.

5. Keep 

TV set, radio and the like 1 m or more away from the unit

.

6. A

void locations exposed to machine oil vapo

r

, salty air (facing 

the seashore, for example), hot spring vapor sulfur gas, etc. Such 

location can cause breakdown.

7. A

void locations exposed to muddy water (along a road, for exam

-

ple) or where the unit can be tampered with.

8. 

Select a location where the outgoing air or operating noise can

-

not annoy

 others.

9. Keep the air outlet opening free of any obstacle.

 

This could a

ffect 

the performance of the unit and create loud noises.

T

rap

This manual describes the installation of outdoor unit only

For the installation of the indoor unit, see the installation manual accompanying indoor unit.

B508

Carefully read and follow these instructions for 

smooth and trouble-free installation.

90°

A

Outdoor unit

Indoor unit

AU-X3M24RV

37

9

557

Piping cover

SAFETY PRECAUTIONS

 T

ighten the flare nut with a torque wrench according to the specifi

ed 

method. 

If the flare nut is tightened too hard, the flare nut may be broken after a long 

time and cause refrigerant gas leakage.

 When installing the unit

,

 take care not to enter air substance other than 

the specified refrigerant(R410A) in the refrigerant cycle. 

Otherwise, it will cause burst and injury as a result of abnormal high pres

-

sure in the refrigerant cycle.

 

Be sure to connect the refrigerant pipe before running the compre

ssor

Otherwise, it will cause burst and injury as a result of abnormal high pres

-

sure in the refrigerant cycle. 

 

Earth the unit. 

Incomplete earth may cause electrical shock.

 

Install an earth leakage breaker to avoid electric shock in case of leak.

Use the current-activated, high-sensitivit

y

, high-speed type breaker with a 

rated sensitivity current of below 30 m

A

 and an operating time of below 0.1 

second.

 

Arrange the drain hose to ensure smooth drainage.

Insufficient drainage may cause wetting of the room, furniture etc.

 

This room air conditioner uses refrigerant R410A.

Use the 

pipe, flare nut and tools exclusively for R410A

.

PIPING

Fit the drain joint into the 

drain tray and connect the 

drain port.

Drain hose (Commercially available)

Inside diameter: ø16 mm

Drain port

Drain tray  3

Drain joint  4 

NOTES ON LOCATIONS

 

Before  inst

alla

tion

,

  re

m

o

v

e  the 

p

a

cking  p

a

d  fro

m

  the  outdoor 

unit.

Packing pad

T

ool

A

R410A

 tool

0 - 0.5 mm

Conventional tool 1.0 - 1.5 mm

300 

mm or more

Wrench

Torque wrench

 

Installation must be made in accordance with the installation 

manual by 

qualified service personnel. 

Incorrect work will cause electric shock, water leak, fire.

 

Be sure to use the attached accessories parts and specified parts 

for installation.

Use of other parts will cause electric shock, water leak, fire, the unit 

falling.

 

The appliance shall be installed in accordance with national wir

-

ing regulations.

W

rong connection can cause overheating or fire.

 

After installation has complete, check that there is no leakage of 

refrigerant gas.

If the refrigerant gas contact with fire, it may generate toxic gas.

 V

entilate the room if refrigerant gas leaks during installation.

If the refrigerant gas contact with fire, it may generate toxic gas.

 

Use the specified electrical cable.

Make sure the cable is secured in place and that the terminals are free 

of any excess force from the cable. Otherwise overheating or fire may 

result.

 Form the cable so that the control box cover

, the cord holder and 

cable holder are not loose. 

Otherwise overheating, fire or electric shock may result.

Coating tape 

(Commercially available)

 

Max. piping 

length:A

Max. total piping length of all 

unit

Min. piping 

length:A

Max. height di

f

ference:

B

C

D

25 m

50 m(2 units) / 60 m(3 units)

3 m

10 m 10 m 10 m

1. 

Standard piping length is 5 m.

2. 

When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the hose’s lead-in port. 

Use the refrigerant pipes shown in the table below.

Pipe size

Pipe thickness

Thermal insulation 

Liquid side

1/4" (ø 6.35 mm)

0.8 mm

Thickness: 6 mm or thicker

Material: Polyethylene foam

Gas side

3/8" (ø 9.52 mm)
1/2" (ø 12.7 mm)

 

The thermal insulation should cover both the gas and liquid pipes. 

Flare nut tightening torque

Pipe size

Torque

Liquid side

1/4" (ø 6.35 mm) 16±2 N·m (1.6±0.2 kgf·m)

Gas side

3/8" (ø 9.52 mm) 38±4 N·m (3.8±0.4 kgf·m)
1/2" (ø 12.7 mm) 55 ± 5 N·m (5.5 ± 0.5 kgf·m)

*18000BTU/h 

class

Note:

• Make sure the flare nuts of the outdoor unit are securely clo

sed for those not connected to the indoor unit.

Joint (1/2" 

 3/8")  5

   

6

  

g

n

ir

 

l

a

e

S

Flare nut (3/8")  7

*Make sure to connect 18000BTU/h-class indoor 

unit to the port “A-UNIT”.

Outdoor unit

Indoor unit

A3AUX3M24RV.indd   1

Reviews: