background image

AYXP7FR

1 – 2

2. AY-XP9FR – AE-X9FR

MODEL

INDOOR UNIT

OUTDOOR UNIT

ITEMS

AY-XP9FR

AE-X9FR

Cooling capacity(Min. > Max.)

kW

2.64 (0.9 - 3.0)

Heating capacity(Min. > Max.)

kW

3.1 (0.9 - 4.8)

Moisture removal(at cooling)

Liters/h

Electrical data

Phase

Single

Rated frequency

Hz

50

Rated voltage

V

230

Rated current 

(Min - Max.)

Cool

A

3.7 (1.0 - 4.8)

Heat

A

3.5 (0.9 - 6.1)

Rated input 

(Min - Max.)

Cool

W

780 (200 - 960)

Heat

W

730 (160 - 1400)

Power factor 

Cool

%

92

Heat

%

91

Compressor

Type

Hermetically sealed rotary type

Model

DA89X1F-23F

Oil charge

370cc (VG74)

Refrigerant system

Evaporator

Louver Fin and Grooved tube type

Condenser

Corrugate Fin and Grooved tube type

Control

Expansion valve

Refrigerant (R410A)

830g

De-lce system

 Micro computer controled reversed systems

Noise level
(at cooling)

High

dB(A)

39

45

Low

dB(A)

Soft

dB(A)

28

Fan system

Drive

Direct drive

Air flow quantity
(at cooling)

High

m3/min.

8.6

23.3

Low

m3/min.

7.3

Soft

m3/min.

5.5

Fan

Cross flow fan

Propeller fan

Connections

Refrigerant coupling

Flare type

Refrigerant tube size Gas, Liquid

3/8", 1/4"

Drain piping mm

O.D 

φ

18

Others

Safety device

Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control

Air filters

Polypropylene net (Washable)

Net dimensions

Width

mm

790

730

Height

mm

278

540

Depth

mm

198

250

Net weight

kg

10

33

Summary of Contents for AY-XP12FR

Page 1: ...CONDITION 4 1 3 TEMPERATURE AT EACH PART AND PRESSURE IN 3 WAY VALVE 4 1 4 PERFORMANCE CURVES 4 2 CHAPTER 5 DISASSEMBLING PROCEDURE 1 DISASSEMBLY OF INDOOR UNIT 5 1 2 DISASSEMBLY OF OUTDOOR UNIT 5 7 REPLACEMENT PARTS LIST SERVICE MANUAL AYXP7FR S6512AYXP7FR T SHARP CORPORATION CONTENTS Parts marked with are important for maintaining the safety of the set Be sure to replace these parts with specifi...

Page 2: ...70cc VG74 Refrigerant system Evaporator Louver Fin and Grooved tube type Condenser Corrugate Fin and Grooved tube type Control Expansion valve Refrigerant R410A 830g De lce system Micro computer controled reversed systems Noise level at cooling High dB A 37 45 Low dB A Soft dB A 28 Fan system Drive Direct drive Air flow quantity at cooling High m3 min 8 0 23 2 Low m3 min 6 8 Soft m3 min 5 5 Fan Cr...

Page 3: ...aporator Louver Fin and Grooved tube type Condenser Corrugate Fin and Grooved tube type Control Expansion valve Refrigerant R410A 830g De lce system Micro computer controled reversed systems Noise level at cooling High dB A 39 45 Low dB A Soft dB A 28 Fan system Drive Direct drive Air flow quantity at cooling High m3 min 8 6 23 3 Low m3 min 7 3 Soft m3 min 5 5 Fan Cross flow fan Propeller fan Conn...

Page 4: ...c RB68A or Freol Alpha 68M Refrigerant system Evaporator Louver Fin and Grooved tube type Condenser Corrugate Fin and Grooved tube type Control Expansion valve Refrigerant R410A 1030g De lce system Micro computer controled reversed systems Noise level at cooling High dB A 40 48 Low dB A Soft dB A 28 Fan system Drive Direct drive Air flow quantity at cooling High m3 min 9 8 26 7 Low m3 min 8 5 Soft...

Page 5: ...AYXP7FR 1 4 2 EXTERNAL DIMENSION 1 Indoor unit 2 Outdoor unit 278 198 790 22 0 58 18 5 175 INVERTER AIR CONDITIONER 250 165 167 5 136 81 730 72 540 299 324 515 12 37 5 4 5 58 135 14 ...

Page 6: ...AYXP7FR 1 5 3 WIRING DIAGRM 1 Indooa unit 2 Outdooa unit 2 1 AE X7FR AE X9FR 2 2 AE X12FR 420V 750μF 420V 750μF ...

Page 7: ...to 10 minutes after self diagnosis is performed during operation and the display returns to normal condition after this display period The content of self diagnosis cannot be called out by the self diagnosis display function of the outdoor unit Example of self diagnosis display on outdoor unit Compressor high temperature error c The content of diagnosis is transferred to the indoor unit via serial...

Page 8: ...ion 4 Temporary stop due to 2 way valve freeze 3 Temporary stop for cycle pro tection Indoor unit in operation Outdoor unit in tempo rary stop 3 times 3 0 Dry operation Temporary stop due to dehumidifying operation 3 Temporary stop for cycle pro tection Indoor outdoor units in complete shutdown 5 times 5 0 Outdoor unit thermistor open circuit Heat exchanger thermistor open cir cuit error 1 Check c...

Page 9: ... unit fan motor 3 AC current defi ciency error 1 Check if there is an open circuit in the secondary winding of the current transformer of the outdoor unit control PWB 1 Replace the outdoor unit control PWB assembly 2 Check if the refrigerant volume is abnormally low 2 Charge the specified amount of refrigerant 3 Check if the refrigerant flows properly 3 Correct refrigerant clogs 2 way valve 3 way ...

Page 10: ...er supply 2 No abnormality found in above inspection 1 2 Replace the outdoor unit control PWB assembly Indoor outdoor units in operation 1 PAM clock error 1 Check the PAM clock for proper input 1 Replace the outdoor unit control PWB assembly Indoor unit in operation Outdoor unit in complete shutdown 17 0 Wires between units Serial open circuit 1 Check the wires between units 1 Connect stable power...

Page 11: ... control PWB Indoor outdoor units in operation 20 0 Indoor unit con trol PCB EEPROM data error EEPROM read data error Replace the indoor unit control PWB Indoor outdoor units in operation 88 Control and dis play PCB Communication error 1 Check for disconnected connector between control PCB and display PCB and open circuit in lead wires 1 Insert connectors cor rectly or replace con trol PWB 2 Check...

Page 12: ...alfunction code is called out 3 Indoor unit relay Malfunction diagnosis display Relays turns Off after about 30 minutes None Displays 18 0 when malfunction code is called out 4 Indoor unit relay Malfunction diagnosis display Turns On momentarily then turns Off 18 1 5 Indoor unit relay Malfunction diagnosis display Turns On momentarily then turns Off 18 1 Indoor unit Outdoor unit 1 N 2 1 N 2 Indoor...

Page 13: ...ng 1 2 At Heating 2 AY XP9FR 2 1 At Cooling 2 2 At Heating 25 30 35 40 2 0 2 2 2 4 2 6 300 400 500 600 Cooling capacity kW Outside air temp ºC Input W 5 0 7 5 10 1 5 2 0 2 5 3 0 500 600 400 Heating capacity kW Outside air temp ºC Input W 25 30 35 40 2 4 2 6 2 8 3 0 3 2 900 600 700 800 Cooling capacity kW Outside air temp ºC Input W 5 0 5 7 10 3 0 2 5 3 5 2 0 700 800 600 Heating capacity kW Outside...

Page 14: ...1 At Cooling 3 2 At Heating 25 30 35 40 3 2 3 4 3 6 3 8 4 0 1200 900 1000 1100 Cooling capacity kW Outside air temp ºC Input W 5 0 5 7 10 3 5 4 0 4 5 3 0 2 5 1000 1100 1200 900 800 Heating capacity kW Outside air temp ºC Input W ...

Reviews: